EUVIMEDEUVIMED entdecken
Vergleichsstudie

Lesion characteristics using high‐frequency low‐tidal volume ventilation versus standard ventilation during ablation of paroxysmal atrial fibrillation

Xiaoxiao Qian iD, Paul C Zei iD, Jose Osorio, Daniela Hincapie iD, Mohamed Gabr, Adelqui Peralta, Andres F Miranda-Arboleda, Bruce A Koplan iD, Carolina Hoyos, Carlos D Matos iD, Nestor Lopez-Cabanillas, Nathaniel A Steiger und 7 weitere

Journal of Cardiovascular Electrophysiology · 2024-10 · 35 (10) · 1962-1971

DOI: 10.1111/jce.16393 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, online erschienen am 07.08.2024. Verfasst von Xiaoxiao Qian und 18 weiteren Autor:innen. Beteiligte Einrichtung: Cardiac Arrhythmia Service, Division of Cardiovascular Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Pulmonary Veins, Heart Rate. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

High‐frequency low‐tidal‐volume (HFLTV) ventilation during radiofrequency catheter ablation (RFCA) for paroxysmal atrial fibrillation (PAF) has been shown to be superior to standard ventilation (SV) in terms of procedural efficiency, acute and long‐term clinical outcomes. Our study aimed to compare ablation lesions characteristics utilizing HFLTV ventilation versus SV during RFCA of PAF.

Methods

A retrospective analysis was conducted on patients who underwent pulmonary vein isolation (PVI) for PAF between August 2022 and March 2023, using high‐power short‐duration ablation. Thirty‐five patients underwent RFCA with HFLTV ventilation and were matched with another cohort of 35 patients who underwent RFCA with SV. Parameters including ablation duration, contact force (CF), impedance drop, and ablation index were extracted from the CARTONET database for each ablation lesion.

Results

A total of 70 patients were included (HFLTV = 35/2484 lesions, SV = 35/2830 lesions) in the analysis. There were no differences in baseline characteristics between the groups. While targeting the same ablation index, the HFLTV ventilation group demonstrated shorter average ablation duration per lesion (12.3 ± 5.0 vs. 15.4 ± 8.4 s, p < .001), higher average CF (17.0 ± 8.5 vs. 10.5 ± 4.6 g, p < .001), and greater impedance reduction (9.5 ± 4.6 vs. 7.7 ± 4.1 ohms, p < .001). HFLTV ventilation group also demonstrated shorter total procedural time (61.3 ± 25.5 vs. 90.8 ± 22.8 min, p < .001), ablation time (40.5 ± 18.6 vs. 65.8 ± 22.5 min, p < .001), and RF time (15.3 ± 4.8 vs. 22.9 ± 9.7 min, p < .001).

Conclusion

HFLTV ventilation during PVI for PAF was associated with improved ablation lesion parameters and procedural efficiency compared to SV.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCatheter AblationPulmonary VeinsHeart RateHumansFemaleMaleRetrospective StudiesMiddle AgedTreatment OutcomeAgedTime FactorsAction PotentialsDatabases, Factual

Stichwörter der Autor:innen

ablation lesions characteristicscatheter ablationhigh‐frequency low‐tidal volume ventilationparoxysmal atrial fibrillationpulmonary vein isolationstandard ventilation

Autor:innen und Institutionen

  • Cardiac Arrhythmia Service, Division of Cardiovascular Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
  • Cardiac Arrhythmia Service, HCA, Miami, Florida, USA.
  • VA Boston Healthcare System, Harvard Medical School, Boston, Massachusetts, USA.
  • Electrophysiology Section, Adventist Cardiovascular Institute, Buenos Aires, Argentina.
  • Cardiac Electrophysiology Section, University of Texas Health Sciences Center San Antonio, San Antonio, Texas, USA.

ORCID-Profile: Xiaoxiao Qian, Paul C Zei, Daniela Hincapie, Bruce A Koplan, Carlos D Matos, Isabella Alviz, Sunil Kapur, William H Sauer, Jorge E Romero

Zitieren

APA

Qian, X., Zei, P. C., Osorio, J., Hincapie, D., Gabr, M., Peralta, A., Miranda-Arboleda, A. F., Koplan, B. A., Hoyos, C., Matos, C. D., Lopez-Cabanillas, N., Steiger, N. A., Velasco, A., Alviz, I., Kapur, S., Tadros, T. M., Tedrow, U. B., Sauer, W. H., & Romero, J. E. (2024). Lesion characteristics using high‐frequency low‐tidal volume ventilation versus standard ventilation during ablation of paroxysmal atrial fibrillation. Journal of Cardiovascular Electrophysiology, 35(10), 1962-1971. https://doi.org/10.1111/jce.16393

Vancouver

Qian X, Zei PC, Osorio J, Hincapie D, Gabr M, Peralta A, et al. Lesion characteristics using high‐frequency low‐tidal volume ventilation versus standard ventilation during ablation of paroxysmal atrial fibrillation. Journal of Cardiovascular Electrophysiology. 2024;35(10):1962-1971. doi:10.1111/jce.16393

BibTeX
@article{Qian2024,
  author = {Qian, Xiaoxiao and Zei, Paul C and Osorio, Jose and Hincapie, Daniela and Gabr, Mohamed and Peralta, Adelqui and Miranda-Arboleda, Andres F and Koplan, Bruce A and Hoyos, Carolina and Matos, Carlos D and Lopez-Cabanillas, Nestor and Steiger, Nathaniel A and Velasco, Alejandro and Alviz, Isabella and Kapur, Sunil and Tadros, Thomas M and Tedrow, Usha B and Sauer, William H and Romero, Jorge E},
  title = {Lesion characteristics using high‐frequency low‐tidal volume ventilation versus standard ventilation during ablation of paroxysmal atrial fibrillation},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2024},
  volume = {35},
  number = {10},
  pages = {1962--1971},
  doi = {10.1111/jce.16393}
}
Kostenlos starten →