Differential gap location after radiofrequency versus cryoballoon pulmonary vein isolation: Insights from a randomized trial with protocol‐mandated repeat procedure
Journal of Cardiovascular Electrophysiology · 2023
DOI: 10.1111/jce.15821 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2023. Verfasst von Samuel K Sørensen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Copenhagen University Hospital Gentofte, Hellerup, Denmark. Hauptthemen laut MEDLINE: Cryosurgery, Pulmonary Veins, Atrial Fibrillation, Catheter Ablation. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Abstract (Originalsprache)
Introduction
Reconnections to pulmonary vein (PV) triggers of atrial fibrillation (AF) are the primary cause of AF recurrence after PV isolation (PVI) with radiofrequency (RF) or cryoballoon catheter ablation (CRYO), but method‐specific contributions to PV reconduction pattern and conductive gap location are incompletely understood.
Methods
The objective of this radiofrequency versus cryoballoon catheter ablation for paroxysmal atrial fibrillation substudy was to determine procedure‐specific patterns of PV reconduction in a randomized population with protocol‐mandated repeat procedures, irrespective of AF recurrence. Each PV was assessed in turn and PV reconnection sites were identified by high‐density electroanatomical mapping and locating the earliest activation site. Gap locations were verified by PV re‐isolation.
Results
In 98 patients, 81% versus 76% previously isolated PVs remained isolated after CRYO versus RF (risk ratio [RR]: 1.06; 95% confidence interval [CI]: 0.96–1.18; p = .28). There were no significant differences for any PV: left superior PV: 90% versus 80%; left inferior PV: 80% versus 78%; right superior PV: 81% versus 80%, and right inferior PV: 76% versus 73%. For each reconnected PV, 34% of ipsilateral PVs were also reconnected after CRYO compared with 64% after RF (RR: 0.54; 95% CI: 0.32–0.90; p = .01). After RF, gaps were clustered by the carina and adjacent segments, whereas they were more heterogeneously distributed after CRYO.
Conclusion
Although RF and CRYO produce similar proportions of durably isolated PVs, gap locations appear to develop in procedure‐specific patterns. After RF, ipsilateral PV reconduction is more frequent and gap sites cluster by the carina, suggesting that this region should be selectively ablated for more durable PVI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Copenhagen University Hospital Gentofte, Hellerup, Denmark.
ORCID-Profile: Samuel K Sørensen, Arne Johannessen, René Worck, Morten L Hansen, Martin H Ruwald
Zitieren
APA
Sørensen, S. K., Johannessen, A., Worck, R., Hansen, M. L., Ruwald, M. H., & Hansen, J. (2023). Differential gap location after radiofrequency versus cryoballoon pulmonary vein isolation: Insights from a randomized trial with protocol‐mandated repeat procedure. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.15821
Vancouver
Sørensen SK, Johannessen A, Worck R, Hansen ML, Ruwald MH, Hansen J. Differential gap location after radiofrequency versus cryoballoon pulmonary vein isolation: Insights from a randomized trial with protocol‐mandated repeat procedure. Journal of Cardiovascular Electrophysiology. 2023. doi:10.1111/jce.15821
BibTeX
@article{Srensen2023,
author = {Sørensen, Samuel K and Johannessen, Arne and Worck, René and Hansen, Morten L and Ruwald, Martin H and Hansen, Jim},
title = {Differential gap location after radiofrequency versus cryoballoon pulmonary vein isolation: Insights from a randomized trial with protocol‐mandated repeat procedure},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2023},
doi = {10.1111/jce.15821}
}
EUVIMED