Kurz gefasst

Fachartikel in der Zeitschrift Equine Veterinary Journal, 2025. Verfasst von Jorge Izquierdo-Moreno und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Animal Medicine and Surgery, Veterinary Faculty, Complutense University of Madrid, Madrid, Spain. Hauptthemen laut MEDLINE: Hypnotics and Sedatives, Ataxia, Imidazoles. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

An accurate evaluation of the degree of sedation is mandatory to adjust the dosage of sedative drugs.

Objectives

To determine the correlation between head height above the ground and ataxia degree in horses sedated with detomidine and the correlation existing between accelerometric variables and both parameters. Study design In vivo experiment.

Methods

Twelve horses were given 0.01 mg/kg of detomidine hydrochloride iv. Measured accelerometric parameters, with one accelerometer positioned between both sacral tuberosities, included speed, stride frequency and length, regularity, dorsoventral, longitudinal, mediolateral and total accelerometric activities, relative force index and dorsoventral, longitudinal and mediolateral parts of the accelerometric activities. Head height above the ground (cm) and subjective ataxia degree were also measured. Baseline values (−15 min) and values measured 5 and 15 min after the injection and then every 15 min for a period of 2 h were obtained.

Results

There was a negative and strong correlation between head height above the ground and ataxia degree (Pearson r = −0.78, p < 0.001), particularly during the first 45 min. A significant correlation was found between head height above the ground and almost all accelerometric parameters. This correlation was very strong with stride frequency, regularity and dorsoventral and total accelerometric activities in both cases, but for ataxia, also with total accelerometric activity. Main limitations Experimental conditions may not represent real clinical situations.

Conclusions

Stride frequency and regularity are the most reliable parameters to determine degree of sedation and are related to the sedation produced. Ataxia should not be considered a separate property of sedation and does not need to be assessed separately to the depth of sedation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hypnotics and SedativesAtaxiaImidazolesAnimalsHorsesBiomechanical PhenomenaMaleFemaleAccelerometry

Stichwörter der Autor:innen

accelerometryanaesthesiaataxiagait analysishorsesedation

Substanzen

detomidineHypnotics and SedativesImidazoles

Autor:innen und Institutionen

  • Department of Animal Medicine and Surgery, Veterinary Faculty, Complutense University of Madrid, Madrid, Spain.

ORCID-Profile: Gabriel Manso-Díaz, Javier López-Sanromán

Zitieren

APA

Izquierdo-Moreno, J., de Paz, M. I., Manso-Díaz, G., Villalba-Orero, M., & López-Sanromán, J. (2025). Correlation between kinematic parameters, ataxia and ground‐to‐lip distance in detomidine sedated horses. Equine Veterinary Journal. https://doi.org/10.1111/evj.14207

Vancouver

Izquierdo-Moreno J, de Paz MI, Manso-Díaz G, Villalba-Orero M, López-Sanromán J. Correlation between kinematic parameters, ataxia and ground‐to‐lip distance in detomidine sedated horses. Equine Veterinary Journal. 2025. doi:10.1111/evj.14207

BibTeX
@article{IzquierdoMoreno2025,
  author = {Izquierdo-Moreno, Jorge and de Paz, Marta Illán and Manso-Díaz, Gabriel and Villalba-Orero, María and López-Sanromán, Javier},
  title = {Correlation between kinematic parameters, ataxia and ground‐to‐lip distance in detomidine sedated horses},
  journal = {Equine Veterinary Journal},
  year = {2025},
  doi = {10.1111/evj.14207}
}
Kostenlos starten →