EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudieOpen Access · CC BY 4.0

Comfort and Usability of Digital Versus Conventional Custom‐Fit Mouthguards: A Randomized Clinical Trial

Maryuri Macías Bautista iD, Priscilla Barbosa Ferreira Soares iD, Airin Karelys Avendaño Rondon iD, Laryssa Silva da Cunha iD, Ianca Daniele Oliveira de Jesus iD, Rodrigo Silva Moreira iD, Gisele Rodrigues da Silva iD, Liran Levin iD, Carlos José Soares iD

Dental Traumatology · 2026-10 · 42 (5) · 592-605

DOI: 10.1111/edt.70059 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Dental Traumatology, online erschienen am 28.01.2026. Verfasst von Maryuri Macías Bautista und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dentistry and Dental Materials, Faculty of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil. Hauptthemen laut MEDLINE: Mouth Protectors, Printing, Three-Dimensional. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa do Estado de Minas Gerais, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives The use of mouthguards protects teeth and the supporting tissues against impacts. Digital impressions and 3D‐printed models can reduce manufacturing steps and minimize discomfort. This study evaluated the fit, comfort, and usability of custom‐made mouthguards, obtained by conventional and digital workflow, in amateur athletes. Materials and Methods Amateur athletes were recruited for this randomized, double‐blind, crossover clinical study. Each participant received two 4‐mm‐thick custom‐fit mouthguards made of ethylene vinyl acetate (EVA) sheets using two protocols: conventional impression using alginate to produce dental stone cast (CMP) and intraoral digital scanning to produce 3D‐printed resin models (DMP). Each mouthguard was worn during all training and matches over 3 months. The order of mouthguard use was randomly assigned. Patient satisfaction with the impression protocol and mouthguard use, model accuracy, and mouthguard fit were assessed.

Results

Overall, 46 participants completed the study. The DMP protocol required less execution time ( p = 0.023), caused less discomfort ( p = 0.018), anxiety ( p = 0.008), nausea ( p = 0.027), difficulty breathing ( p < 0.001), and unpleasant taste ( p = 0.006) compared to the CMP protocol. The pain ( p = 0.971) perceived by the participants was similar in both impression protocols. The CMP‐mouthguards were considered to be better fitting by the majority of participants ( p = 0.027). Between‐group comparisons revealed that DMP‐mouthguard caused less discomfort immediately postadaptation ( p = 0.034), with no significant differences observed at 30 or 90 days.

Conclusions

The digital workflow demonstrated to be efficient in the fabrication of mouthguards. Digital impression was more comfortable, requiring less execution time, with more accurate printed models and produced mouthguards with reported comfort and fit levels similar to those manufactured conventionally.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mouth ProtectorsPrinting, Three-DimensionalHumansCross-Over StudiesDouble-Blind MethodMaleFemaleEquipment DesignAdultModels, DentalPatient SatisfactionPolyvinylsDental Impression TechniqueYoung Adult

Stichwörter der Autor:innen

3D printingathlete injuriesdental traumaprotective equipmentsports dentistry

Substanzen

Polyvinyls

Autor:innen und Institutionen

  • Department of Dentistry and Dental Materials, Faculty of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.
  • Department of Periodontics and Implantology, Faculty of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.
  • College of Dentistry, University of Saskatchewan, Saskatoon, Saskatchewan, Canada.

ORCID-Profile: Maryuri Macías Bautista, Priscilla Barbosa Ferreira Soares, Airin Karelys Avendaño Rondon, Laryssa Silva da Cunha, Ianca Daniele Oliveira de Jesus, Rodrigo Silva Moreira, Gisele Rodrigues da Silva, Liran Levin, Carlos José Soares

Förderung

  • Conselho Nacional de Desenvolvimento Científico e Tecnológico
  • Fundação de Amparo à Pesquisa do Estado de Minas Gerais
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Zitieren

APA

Macías Bautista, M., Soares, P. B. F., Rondon, A. K. A., da Cunha, L. S., de Jesus, I. D. O., Moreira, R. S., da Silva, G. R., Levin, L., & Soares, C. J. (2026). Comfort and Usability of Digital Versus Conventional Custom‐Fit Mouthguards: A Randomized Clinical Trial. Dental Traumatology, 42(5), 592-605. https://doi.org/10.1111/edt.70059

Vancouver

Macías Bautista M, Soares PBF, Rondon AKA, da Cunha LS, de Jesus IDO, Moreira RS, et al. Comfort and Usability of Digital Versus Conventional Custom‐Fit Mouthguards: A Randomized Clinical Trial. Dental Traumatology. 2026;42(5):592-605. doi:10.1111/edt.70059

BibTeX
@article{MacasBautista2026,
  author = {Macías Bautista, Maryuri and Soares, Priscilla Barbosa Ferreira and Rondon, Airin Karelys Avendaño and da Cunha, Laryssa Silva and de Jesus, Ianca Daniele Oliveira and Moreira, Rodrigo Silva and da Silva, Gisele Rodrigues and Levin, Liran and Soares, Carlos José},
  title = {Comfort and Usability of Digital Versus Conventional Custom‐Fit Mouthguards: A Randomized Clinical Trial},
  journal = {Dental Traumatology},
  year = {2026},
  volume = {42},
  number = {5},
  pages = {592--605},
  doi = {10.1111/edt.70059}
}
Kostenlos starten →