EUVIMEDEUVIMED entdecken
CrossrefInfokarte

A Multicenter Prospective Study on the Safety and Efficacy of the New Low Axial Force Self‐Expandable Metallic Stent With Slim Delivery System for Malignant Colorectal Obstruction

Takeshi Mizumoto, Yuzuru Tamaru, Toshio Kuwai, Akihisa Matsuda, Shuji Saito, Satoshi Ikeda, Kazuhiro Hiyama, Hirofumi Chiba, Yorinobu Sumida, Takaaki Yoshikawa, Chikako Tokoro, Tetsuro Maruyama, Hiroyuki Isayama, Yoshihisa Saida

Digestive Endoscopy · 2026-06 · 38 (6)

DOI: 10.1111/den.70185 ↗
AbstractBibliografische Angaben

Abstract

ABSTRACT Objectives Self‐expandable metallic stents are widely used for malignant colorectal obstruction, and low axial force (AF) stents have been developed to reduce adverse events. The Niti‐S Enteral Colonic Uncovered Stent (MD/BB type) is a new low‐AF stent that maintains a 22 mm outer diameter despite using a 9Fr delivery system. This improves placement performance and reduces adverse events. We aim to evaluate the efficacy and safety of this stent. Methods In this prospective, multicenter clinical study, we assess the efficacy and safety of the low‐AF Niti‐S MD/BB stent for colonic stenting. Of the 199 consecutive registered patients who underwent colorectal stenting with the Niti‐S MD/BB stents at 12 centers affiliated with the Japan Colonic Stent Safe Procedure Research Group between February 2019 and March 2023, 193 were included for analysis. The primary endpoint was the clinical success rate. The secondary endpoints included technical success and adverse events. Results The technical success rate was 98.4% (190/193), and the clinical success rate was 95.9% (185/193). In all bridge‐to‐surgery cases, elective surgery was successfully performed as planned, and no perforations were observed. In palliative cases, three perforations occurred. Seven patients required surgery in the subsequent year due to adverse events. The 1‐year stent patency rate in PAL cases was 80.6%. Conclusion This new low‐AF Niti‐S MD/BB stent demonstrated excellent safety and efficacy, with high technical and clinical success rates and a low incidence of adverse events. Thus, low‐AF stents may be a safe, user‐friendly option for obstructive colorectal cancer.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →