The impact of defects of the atrial septum on procedural complexity, complications, and outcomes of transvenous lead extraction
Clinical Physiology and Functional Imaging · 2026-11 · 46 (6)
DOI: 10.1111/cpf.70101 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Physiology and Functional Imaging, online erschienen am 29.10.2026. Verfasst von Dorota Nowosielecka und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Surgery, The Pope John Paul II Province Hospital, Zamość, Poland. Hauptthemen laut MEDLINE: Device Lead Extraction, Heart Septal Defects, Atrial, Postoperative Complications, Pacemaker, Artificial. Die Arbeit nennt 44 Literaturangaben. Gefördert von: Śląski Uniwersytet Medyczny w Katowicach.
Abstract (Originalsprache)
Background
Patients with defects of the atrial septum (DAS) undergoing transvenous lead extraction (TLE) may be at increased risk of systemic embolism due to transient right‐to‐left shunting. However, data on the prevalence and clinical relevance of DAS in patients undergoing TLE remain limited.
Methods
This retrospective study included 3637 patients undergoing TLE between 2006 and 2024 with complete preprocedural assessment of the atrial septum and at least 3 years of follow‐up. We evaluated the prevalence of DAS and its association with procedural complexity, major complications, and survival.
Results
DAS was identified in 3.71% of patients. Patent foramen ovale was present in 2.45%, secundum atrial septal defect in 1.15%, and both defects in 0.08%. Most defects were small, with predominant left‐to‐right shunting. Patients with DAS more frequently had lead‐related infective endocarditis and vegetations on transesophageal echocardiography ( p < 0.001). TLE procedures in patients with DAS were more complex, with longer extraction times and more frequent use of advanced extraction tools. Despite higher predicted procedural risk, the incidence of major complications, including stroke, was low. DAS was not associated with increased in‐hospital, 30‐day, 1‐year, or 3‐year mortality.
Conclusions
In this large TLE cohort, DAS was uncommon and associated with greater procedural complexity, but not with a higher incidence of major complications or worse long‐term survival. Clinically apparent systemic embolic events were rare.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital, Zamość, Poland.
- Faculty of Health Sciences, Academy of Zamość, Zamość, Poland.
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Silesian Medical University in Katowice, Zabrze, Poland.
- Department of Cardiothoracic and Vascular Surgery, German Heart Institute Berlin, Berlin, Germany.
- Department of Physiology, Pathophysiology and Clinical Immunology, Collegium Medicum of Jan Kochanowski University, Kielce, Poland.
- Department of Cardiac Surgery, Swietokrzyskie Cardiology Center, Kielce, Poland.
ORCID-Profile: Dorota Nowosielecka, Wojciech Jacheć, Anna Polewczyk, Dominika Mościcka, Andrzej Kutarski
Förderung
- Śląski Uniwersytet Medyczny w Katowicach
Zitieren
APA
Nowosielecka, D., Jacheć, W., Starck, C., Polewczyk, A., Mościcka, D., & Kutarski, A. (2026). The impact of defects of the atrial septum on procedural complexity, complications, and outcomes of transvenous lead extraction. Clinical Physiology and Functional Imaging, 46(6). https://doi.org/10.1111/cpf.70101
Vancouver
Nowosielecka D, Jacheć W, Starck C, Polewczyk A, Mościcka D, Kutarski A. The impact of defects of the atrial septum on procedural complexity, complications, and outcomes of transvenous lead extraction. Clinical Physiology and Functional Imaging. 2026;46(6). doi:10.1111/cpf.70101
BibTeX
@article{Nowosielecka2026,
author = {Nowosielecka, Dorota and Jacheć, Wojciech and Starck, Christoph and Polewczyk, Anna and Mościcka, Dominika and Kutarski, Andrzej},
title = {The impact of defects of the atrial septum on procedural complexity, complications, and outcomes of transvenous lead extraction},
journal = {Clinical Physiology and Functional Imaging},
year = {2026},
volume = {46},
number = {6},
doi = {10.1111/cpf.70101}
}
EUVIMED