Intra‐ and inter‐observer reliability of ultrasound muscle thickness of gluteal and biceps femoris long head in individuals with and without SCI
Clinical Physiology and Functional Imaging · 2026-01 · 46 (1)
DOI: 10.1111/cpf.70045 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Physiology and Functional Imaging, online erschienen am 08.01.2026. Verfasst von Boas J Wijker und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands. Hauptthemen laut MEDLINE: Hamstring Muscles, Spinal Cord Injuries. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ZonMw.
Abstract (Originalsprache)
Purpose
This study aimed to evaluate both inter‐ and intra‐observer reliability of ultrasound‐based muscle thickness measurements in able‐bodied (AB) individuals, as well as intra‐observer reliability in individuals with spinal cord injury (SCI).
Methods
Ultrasound measurements of the gluteus maximus, medius, minimus and biceps femoris long head were performed on 31 AB participants and 30 participants with SCI. Each AB participant was scanned on two occasions by three observers, with three repetitions per muscle per occasion. The muscle thickness in participants with SCI was measured using three repetitions during a single test occasion, conducted by one observer. A generalizability (G) study was conducted to assess the reliability of the measurements.
Results
In AB participants, intra‐observer reliability for gluteal muscles ranged from G‐coefficient: 0.57 to 0.89, and for biceps femoris long head from G‐coefficient: 0.60 to 0.76. Inter‐observer reliability in AB participants was G‐coefficient:0.48–0.72 for the gluteal muscles and G‐coefficient: 0.52 for the biceps femoris. In contrast, intra‐observer reliability in participants with SCI was excellent across all muscles (G‐coefficient: 0.95–0.99).
Conclusion
Ultrasound can assess muscle thickness with moderate to good intra‐observer reliability in AB participants, but with only poor to moderate inter‐observer reliability. In contrast, intra‐observer reliability was excellent in participants with SCI. Reliability depends on observer experience and varies across muscles and populations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands.
- Amsterdam Rehabilitation Research Center, Reade, Amsterdam, the Netherlands.
- Center of Excellence for Rehabilitation Medicine, University Medical Center Utrecht Brain Center, University Medical Center Utrecht and De Hoogstraat Rehabilitation, Utrecht, the Netherlands.
- Department of Epidemiology and Data Science, Amsterdam UMC, Amsterdam, the Netherlands.
- Amsterdam Public Health Research Institute, Methodology, Amsterdam University Medical Center, Amsterdam, the Netherlands.
- Department of Health Sciences, Faculty of Science, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands.
ORCID-Profile: Boas J Wijker
Förderung
- ZonMw
Zitieren
APA
Wijker, B. J., de Groot, S., Denneman, B., Brouwer, P., Tomaras, V., Haarler, A., Weide, G., Mokkink, L. B., van Dongen, J. M., & Janssen, T. W. J. (2026). Intra‐ and inter‐observer reliability of ultrasound muscle thickness of gluteal and biceps femoris long head in individuals with and without SCI. Clinical Physiology and Functional Imaging, 46(1). https://doi.org/10.1111/cpf.70045
Vancouver
Wijker BJ, de Groot S, Denneman B, Brouwer P, Tomaras V, Haarler A, et al. Intra‐ and inter‐observer reliability of ultrasound muscle thickness of gluteal and biceps femoris long head in individuals with and without SCI. Clinical Physiology and Functional Imaging. 2026;46(1). doi:10.1111/cpf.70045
BibTeX
@article{Wijker2026,
author = {Wijker, Boas J and de Groot, Sonja and Denneman, Britt and Brouwer, Puck and Tomaras, Vasileios and Haarler, Annelaura and Weide, Guido and Mokkink, Lidwine B and van Dongen, Johanna M and Janssen, Thomas W J},
title = {Intra‐ and inter‐observer reliability of ultrasound muscle thickness of gluteal and biceps femoris long head in individuals with and without SCI},
journal = {Clinical Physiology and Functional Imaging},
year = {2026},
volume = {46},
number = {1},
doi = {10.1111/cpf.70045}
}
EUVIMED