Improving sensitivity through data augmentation with synthetic lymph node metastases for AI‐based analysis of PSMA PET‐CT images
Clinical Physiology and Functional Imaging · 2024
DOI: 10.1111/cpf.12879 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Clinical Physiology and Functional Imaging, 2024. Verfasst von Elin Trägårdh und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Translational Medicine and Wallenberg Centre for Molecular Medicine, Lund University, Malmö, Sweden. Hauptthemen laut MEDLINE: Lymphatic Metastasis, Positron Emission Tomography Computed Tomography, Prostatic Neoplasms, Glutamate Carboxypeptidase II. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Region Skåne, Knut och Alice Wallenbergs Stiftelse, Swedish Cancer Foundation.
Abstract (Originalsprache)
Background
We developed a fully automated artificial intelligence (AI)AI‐based‐based method for detecting suspected lymph node metastases in prostate‐specific membrane antigen (PSMA)(PSMA) positron emission tomography‐computed tomography (PET‐CT)(PET‐CT) images of prostate cancer patients by using data augmentation that adds synthetic lymph node metastases to the images to expand the training set.
Methods
Synthetic data were derived from original training images to which new synthetic lymph node metastases were added. Thus, the original training set from a previous study ( n = 420) was expanded by one synthetic image for every original image ( n = 840), which was used to train an AI model. The performance of the AI model was compared to that of nuclear medicine physicians and a previously developed AI model. The human readers were alternately used as a reference and compared to either another reading or AI model.
Results
The new AI model had an average sensitivity of 84% for detecting lymph node metastases compared with 78% for human readings. Our previously developed AI method without synthetic data had an average sensitivity of 79%. The number of false positive lesions were slightly higher for the new AI model (average 3.3 instances per patient) compared to human readings and the previous AI model (average 2.8 instances per patient), while the number of false negative lesions was lower.
Conclusions
Creating synthetic lymph node metastases, as a form of data augmentation, on [18F]PSMA‐1007F]PSMA‐1007 PETPET‐CT‐CT images improved the sensitivity of an AI model for detecting suspected lymph node metastases. However, the number of false positive lesions increased somewhat.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Translational Medicine and Wallenberg Centre for Molecular Medicine, Lund University, Malmö, Sweden.
- Department of Clinical Physiology and Nuclear Medicine, Skåne University Hospital, Malmö, Sweden.
- Eigenvision AB, Malmö, Sweden.
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden.
- Department of Molecular and Clinical Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Förderung
- Region Skåne
- Knut och Alice Wallenbergs Stiftelse
- Swedish Cancer Foundation
- Allmänna Sjukhusets i Malmö Stiftelse för Bekämpande av Cancer
- Swedish Prostate Cancer Foundation
Zitieren
APA
Trägårdh, E., Ulén, J., Enqvist, O., Edenbrandt, L., & Larsson, M. (2024). Improving sensitivity through data augmentation with synthetic lymph node metastases for AI‐based analysis of PSMA PET‐CT images. Clinical Physiology and Functional Imaging. https://doi.org/10.1111/cpf.12879
Vancouver
Trägårdh E, Ulén J, Enqvist O, Edenbrandt L, Larsson M. Improving sensitivity through data augmentation with synthetic lymph node metastases for AI‐based analysis of PSMA PET‐CT images. Clinical Physiology and Functional Imaging. 2024. doi:10.1111/cpf.12879
BibTeX
@article{Trgrdh2024,
author = {Trägårdh, Elin and Ulén, Johannes and Enqvist, Olof and Edenbrandt, Lars and Larsson, Måns},
title = {Improving sensitivity through data augmentation with synthetic lymph node metastases for AI‐based analysis of PSMA PET‐CT images},
journal = {Clinical Physiology and Functional Imaging},
year = {2024},
doi = {10.1111/cpf.12879}
}
EUVIMED