Pure tone audiogram classification using deep learning techniques
Clinical Otolaryngology · 2024-09 · 49 (5) · 595-603
DOI: 10.1111/coa.14170 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Otolaryngology, online erschienen am 15.05.2024. Verfasst von Zhiyong Dou und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Electronic Information and Communications, Huazhong University of Science and Technology, Wuhan, China. Hauptthemen laut MEDLINE: Deep Learning, Audiometry, Pure-Tone, Hearing Loss. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: Hubei Provincial Key Research and Development Program, Wuhan Knowledge Innovation Project, Key Project of Tongji Hospital Scientific Research Fund.
Abstract (Originalsprache)
Objective
Pure tone audiometry has played a critical role in audiology as the initial diagnostic tool, offering vital insights for subsequent analyses. This study aims to develop a robust deep learning framework capable of accurately classifying audiograms across various commonly encountered tasks. Design, Setting, and Participants This single‐centre retrospective study was conducted in accordance with the STROBE guidelines. A total of 12 518 audiograms were collected from 6259 patients aged between 4 and 96 years, who underwent pure tone audiometry testing between February 2018 and April 2022 at Tongji Hospital, Tongji Medical College, Wuhan, China. Three experienced audiologists independently annotated the audiograms, labelling the hearing loss in degrees, types and configurations of each audiogram. Main Outcome Measures A deep learning framework was developed and utilised to classify audiograms across three tasks: determining the degrees of hearing loss, identifying the types of hearing loss, and categorising the configurations of audiograms. The classification performance was evaluated using four commonly used metrics: accuracy, precision, recall and F1‐score.
Results
The deep learning method consistently outperformed alternative methods, including K‐Nearest Neighbors, ExtraTrees, Random Forest, XGBoost, LightGBM, CatBoost and FastAI Net, across all three tasks. It achieved the highest accuracy rates, ranging from 96.75% to 99.85%. Precision values fell within the range of 88.93% to 98.41%, while recall values spanned from 89.25% to 98.38%. The F1‐score also exhibited strong performance, ranging from 88.99% to 98.39%.
Conclusions
This study demonstrated that a deep learning approach could accurately classify audiograms into their respective categories and could contribute to assisting doctors, particularly those lacking audiology expertise or experience, in better interpreting pure tone audiograms, enhancing diagnostic accuracy in primary care settings, and reducing the misdiagnosis rate of hearing conditions. In scenarios involving large‐scale audiological data, the automated classification system could be used as a research tool to efficiently provide a comprehensive overview and statistical analysis. In the era of mobile audiometry, our deep learning framework can also help patients quickly and reliably understand their self‐tested audiograms, potentially encouraging timely consultations with audiologists for further evaluation and intervention.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Electronic Information and Communications, Huazhong University of Science and Technology, Wuhan, China.
- Department of Otolaryngology-Head and Neck Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
- School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan, China.
ORCID-Profile: Zhiyong Dou, Yingqiang Li, Xiang Bai, Dan Bing
Förderung
- Hubei Provincial Key Research and Development Program
- Wuhan Knowledge Innovation Project
- Key Project of Tongji Hospital Scientific Research Fund
- the National Key Research and Development Program of China
Zitieren
APA
Dou, Z., Li, Y., Deng, D., Zhang, Y., Pang, A., Fang, C., Bai, X., & Bing, D. (2024). Pure tone audiogram classification using deep learning techniques. Clinical Otolaryngology, 49(5), 595-603. https://doi.org/10.1111/coa.14170
Vancouver
Dou Z, Li Y, Deng D, Zhang Y, Pang A, Fang C, et al. Pure tone audiogram classification using deep learning techniques. Clinical Otolaryngology. 2024;49(5):595-603. doi:10.1111/coa.14170
BibTeX
@article{Dou2024,
author = {Dou, Zhiyong and Li, Yingqiang and Deng, Dongzhou and Zhang, Yunxue and Pang, Anran and Fang, Cong and Bai, Xiang and Bing, Dan},
title = {Pure tone audiogram classification using deep learning techniques},
journal = {Clinical Otolaryngology},
year = {2024},
volume = {49},
number = {5},
pages = {595--603},
doi = {10.1111/coa.14170}
}