EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Residual Cement Excess of Composite Versus Glass Ionomer Cement in Implant‐Supported Single Crowns After Different Intraoral Exposure Times—A Randomized Controlled Clinical Trial

Maria Weinreuter, Kevin Richter, Thomas Stober, Peter Rammelsberg, Stefanie Kappel

Clinical Oral Implants Research · 2026-06 · 37 (6) · 714-721

DOI: 10.1111/clr.70113 ↗
AbstractBibliografische Angaben

Abstract

ABSTRACT Objective To evaluate the frequency and quantity of residual cement after cementation of monolithic zirconia crowns with glass ionomer or resin composite cement on customized ceramic abutments, following different intraoral retention times. The influence of margin location, quadrant and implant region was also assessed. Materials and Methods 40 patients received cemented monolithic single crowns on customized ceramic abutments of bone‐level implants. They were randomly assigned to four groups: GC0 (glass ionomer, immediate removal), GC4 (glass ionomer, 4 weeks), RC0 (resin composite, immediate), and RC4 (resin composite, 4 weeks). Each crown was fabricated with an occlusal access opening to enable abutment–crown removal. Cementation and excess removal were performed by one experienced clinician. After the specified time, suprastructures were unscrewed and examined for residual cement. Image analysis (GIMP) calculated the ratio of cement‐covered to total abutment and peri‐implant tissue surface. Results Residual cement was detected on 39/40 abutments (97.5%), affecting 137/160 surfaces (85.6%). Median ratios were 0.020 (Q1 0.015, Q3 0.033) in GC0, 0.042 (0.014, 0.087) in GC4, 0.078 (0.054, 0.114) in RC0, and 0.130 (0.074, 0.195) in RC4. Resin cement left significantly more residues than glass ionomer ( p < 0.001). Trends were also observed for margin location and implant region. Radiographs were insufficient to detect interproximal cement. Conclusions Both cements left detectable residues. Resin cement produced significantly larger areas, while retention time did not reduce cement quantity. Glass ionomer appears preferable for implant‐supported single crowns. Trial Registration German Clinical Trials Register (DRKS00004158; DRKS00011743)

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →