EUVIMEDEUVIMED entdecken
Vergleichsstudie

Accuracy of a Novel Intraoral Photogrammetry Technique for Complete‐Arch Implant Impressions: An In Vitro Study

Xiao-Jiao Fu iD, Zheng-Zhen Cai, Jun-Yu Shi, Shi-Chong Qiao, Maurizio S Tonetti iD, Hong-Chang Lai iD, Bei-Lei Liu

Clinical Oral Implants Research · 2025

DOI: 10.1111/clr.14445 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Oral Implants Research, 2025. Verfasst von Xiao-Jiao Fu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Implantology, Shanghai PerioImplant Innovation Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong Univ…. Hauptthemen laut MEDLINE: Photogrammetry, Dental Impression Technique, Dental Implants. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: the Project of Biobank, the Biomaterials and Regenerative Medicine Institute Cooperative Research Project by Shanghai JiaoTong University School of Medicine, the Shanghai Rising Star Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To compare the accuracy of complete‐arch implant impressions using four digital techniques: extraoral photogrammetry ( EPG ), intraoral scanning with original scan body ( IOS ), intraoral scanning with prefabricated aids ( IOSA ), and intraoral photogrammetry ( IPG ). Materials and Methods One edentulous maxillary master model with six parallel abutment analogs was scanned by a laboratory scanner as the reference scan. EPG , IOS , IOSA , and IPG were used to scan the master model with respective scan bodies as test scans. Ten scanning data were gained for each technique. Trueness and precision of root mean square ( RMS ) errors were measured between the test and reference scans. Deviations in distance and angle relative to the reference scan between all pairs of abutment analogs were measured. Scanning time was recorded.

Results

IPG showed significantly best trueness in RMS errors (IPG, 26.37 ± 1.02 μm; EPG, 31.72 ± 0.59 μm; IOS, 39.93 ± 7.98 μm; IOSA, 50.60 ± 12.46 μm), (all p < 0.050). EPG showed significantly best precision in RMS errors (EPG, 2.30 ± 1.31 μm; IPG , 4.12 ± 0.87 μm; IOS , 33.38 ± 13.95 μm; IOSA , 28.35 ± 11.48 μm), (all p < 0.001). IPG demonstrated significantly best performance in distance deviation ( IPG , 28.59 ± 24.75 μm; EPG , 55.55 ± 37.82 μm; IOS , 62.97 ± 50.60 μm; IOSA , 93.37 ± 72.15 μm), (all p < 0.050). No significant differences were found regarding angle deviation ( p = 0.313). IOSA showed the longest scanning duration ( IPG : 50.30 ± 6.77 s; EPG : 57.40 ± 5.19 s; IOS : 91.10 ± 20.31 s; IOSA : 125.00 ± 18.74 s), (all p < 0.001).

Conclusions

IPG achieved comparable accuracy with EPG in complete‐arch implant digital impressions in vitro. IPG offers an efficient and straightforward workflow, making it a valuable alternative method; however, further clinical studies are needed to validate its efficacy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotogrammetryDental Impression TechniqueDental ImplantsHumansIn Vitro TechniquesModels, Dental

Stichwörter der Autor:innen

accuracydental implantintraoral scanphotogrammetry

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Department of Oral and Maxillofacial Implantology, Shanghai PerioImplant Innovation Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong…
  • European Research Group on Periodontology, Genova, Italy.

ORCID-Profile: Xiao-Jiao Fu, Maurizio S Tonetti, Hong-Chang Lai

Förderung

  • the Project of Biobank
  • the Biomaterials and Regenerative Medicine Institute Cooperative Research Project by Shanghai JiaoTong University School of Medicine
  • the Shanghai Rising Star Project
  • the Fundamental Research Funds for the Central Universities
  • Fundamental Research Funds for the Central Universities

Zitieren

APA

Fu, X. J., Cai, Z. Z., Shi, J. Y., Qiao, S. C., Tonetti, M. S., Lai, H. C., & Liu, B. L. (2025). Accuracy of a Novel Intraoral Photogrammetry Technique for Complete‐Arch Implant Impressions: An In Vitro Study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.14445

Vancouver

Fu XJ, Cai ZZ, Shi JY, Qiao SC, Tonetti MS, Lai HC, et al. Accuracy of a Novel Intraoral Photogrammetry Technique for Complete‐Arch Implant Impressions: An In Vitro Study. Clinical Oral Implants Research. 2025. doi:10.1111/clr.14445

BibTeX
@article{Fu2025,
  author = {Fu, Xiao-Jiao and Cai, Zheng-Zhen and Shi, Jun-Yu and Qiao, Shi-Chong and Tonetti, Maurizio S and Lai, Hong-Chang and Liu, Bei-Lei},
  title = {Accuracy of a Novel Intraoral Photogrammetry Technique for Complete‐Arch Implant Impressions: An In Vitro Study},
  journal = {Clinical Oral Implants Research},
  year = {2025},
  doi = {10.1111/clr.14445}
}
Kostenlos starten →