ABSTRACT Introduction Immediate implant placement and provisionalization in the maxillary aesthetic zone necessitates meticulous treatment planning. The integration of intraoral scanning with cone beam computed tomography allows for three‐dimensional prosthetic‐driven planning of the implant. Additionally, it facilitates static computer‐assisted implant surgery and prefabrication of a temporary restoration, enabling chairside restoration of the immediate implant. This study aimed to evaluate the clinical, aesthetic, radiographic, and patient‐reported outcomes after immediate implant placement and restoration. Materials and Methods In a prospective case series, 30 patients with a failing tooth in the maxillary aesthetic zone were included and received immediate implant placement with a bone graft and a prefabricated temporary restoration. The definitive restoration was placed 3 months later. The clinical, aesthetic, radiographic, and patient‐reported outcomes were collected prior to implant treatment, 6 weeks after the temporary restoration, and 1 month and 1 year after the definitive restoration. Results The prefabricated temporary restoration could be placed in all patients. Three cases of early implant failure were observed (implant survival rate 90%); hence, 27 patients were evaluated after 1 year. The survival and success rates were 100% for the temporary and 100% and 96%, respectively, for the definitive restorations. Plaque, bleeding on probing, and peri‐implant inflammation were absent in most cases. At the 1‐year follow‐up, the mean (SD) Pink Esthetic Score and White Esthetic Score (scale 0–20) was 15.4 (2.5). The mean (SD) marginal bone level change between implant placement and the 1‐year follow‐up was −0.18 mm (0.57) on the mesial side and −0.44 mm (1.23) on the distal side. The median buccal bone thickness remained stable after immediate implant placement and grafting. The mean (SD) patient satisfaction (scale 0–10) was 9.2 (0.8) at the 1‐year evaluation. Conclusion The digital workflow has the potential to enable the manufacture of prefabricated temporary restorations, leading to satisfactory clinical, aesthetic, radiographic, and patient‐reported outcomes after immediate placement of single‐tooth implants in the aesthetic zone. Clinical Trial Registration Registered in the National Trial Register (NL8264).

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →