The impact of collagen membrane fixation protocols on volume stability in horizontal ridge augmentation in the aesthetic area: A retrospective study
Clinical Implant Dentistry and Related Research · 2024-12 · 26 (6) · 1354-1365
DOI: 10.1111/cid.13393 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Implant Dentistry and Related Research, online erschienen am 30.09.2024. Verfasst von Shuo Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral Implantology, Tianjin Stomatological Hospital, School of Medicine, Nankai University, Tianjin, China. Hauptthemen laut MEDLINE: Alveolar Ridge Augmentation, Collagen, Cone-Beam Computed Tomography. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Tianjin Health Research Project, Tianjin Natural Science Foundation Multi-Investment Project for Youths, Tianjin Key Laboratory of Oral and Maxillofacial Function Reconstruction Project.
Abstract (Originalsprache)
Objectives
This study aimed to evaluate the impact of different collagen membran fixation protocols on the volume stability in horizontal ridge augmentation in the aesthetic area.
Methods
A total of 48 patients with 65 augmented sites were included in this study. Implants were placed in the aesthetic region, and simultaneous guided bone regeneration (GBR) surgery was performed for horizontal ridge augmentation. Participants were divided into four groups, each comprising 12 patients, based on different absorbable collagen membrane fixation protocols. Group 1: without fixation; Group 2: fixation with absorbable sutures; Group 3: fixation with titanium pins; Group 4: fixation with titanium pins and absorbable sutures. Cone beam computed tomography (CBCT) was performed immediately after surgery and at 6 months post‐surgery, respectively. The horizontal thickness of the augmented region was analyzed for volume stability at the implant shoulder (H0) and 1–5 mm apical to the implant shoulder (H1–H5). Changes in labial thickness during bone healing were calculated as absolute values (mm) and relative values (%).
Results
After 6 months of bone healing, horizontal thickness was significantly reduced at all levels (H0–H5) in all groups compared to immediate post‐surgery results ( p < 0.05). At H1–H5, horizontal bone loss in group 1 was significantly higher than in the other three groups ( p < 0.05). Group 4 exhibited significantly less horizontal bone loss compared to group 2 at H0–H2 ( p < 0.05) and group 4 compared to group 3 at H0–H1 ( p < 0.05). No significant difference in horizontal bone loss between groups 2 and 3 was detected at H0–H5 ( p > 0.05).
Conclusion
Guided bone regeneration in the aesthetic area with additional membrane fixation demonstrated superior volume stability of the augmented region compared to cases without fixation. There was no significant difference in bone volume stability between membrane fixation with titanium pins and fixation with absorbable sutures. However, the combined use of pins and absorbable sutures yielded superior volume stability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Oral Implantology, Tianjin Stomatological Hospital, School of Medicine, Nankai University, Tianjin, China.
- Tianjin Key Laboratory of Oral and Maxillofacial Function Reconstruction, Tianjin, China.
- School of Medicine, Nankai University, Tianjin, China.
ORCID-Profile: Shuo Zhang
Förderung
- Tianjin Health Research Project
- Tianjin Natural Science Foundation Multi-Investment Project for Youths
- Tianjin Key Laboratory of Oral and Maxillofacial Function Reconstruction Project
- Tianjin Key Medical Discipline (Specialty) Construction Project
- Tianjin High-level Personnel Training Program
Zitieren
APA
Zhang, S., Wang, Y., Wang, Q., Li, J., Wang, F., Li, Z., Cui, J., & Zhang, J. (2024). The impact of collagen membrane fixation protocols on volume stability in horizontal ridge augmentation in the aesthetic area: A retrospective study. Clinical Implant Dentistry and Related Research, 26(6), 1354-1365. https://doi.org/10.1111/cid.13393
Vancouver
Zhang S, Wang Y, Wang Q, Li J, Wang F, Li Z, et al. The impact of collagen membrane fixation protocols on volume stability in horizontal ridge augmentation in the aesthetic area: A retrospective study. Clinical Implant Dentistry and Related Research. 2024;26(6):1354-1365. doi:10.1111/cid.13393
BibTeX
@article{Zhang2024,
author = {Zhang, Shuo and Wang, Yanying and Wang, Qingfu and Li, Jinmeng and Wang, Feifan and Li, Zhaoyang and Cui, Jianlin and Zhang, Jian},
title = {The impact of collagen membrane fixation protocols on volume stability in horizontal ridge augmentation in the aesthetic area: A retrospective study},
journal = {Clinical Implant Dentistry and Related Research},
year = {2024},
volume = {26},
number = {6},
pages = {1354--1365},
doi = {10.1111/cid.13393}
}
EUVIMED