EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Interlaboratory performance testing on EPIC v2.0 CNS tumor profiling demonstrates high reproducibility of tumor classification but reveals the need for harmonized copy number variation reporting

Katrin Mauch‐Mücke, Christin Siewert, Lora Dimitrova, Sandra Pohl, Brendan Osberg, Annika K. Wefers, Julia Lorenz, Tanja Rothhammer‐Hampl, Till Acker, Alonso Barrantes‐Freer, Jean Boutonnat, Bérengère Dadone‐Montaudié, Claire Delbridge, Wolfgang Dietmaier, Sebastian Dintner, Hildegard Dohmen, Matthias Dottermusch, Daniel Erny, Katrin B. M. Frauenknecht, Tobias Goschzik, Patrick N. Harter, Daniela Hirsch, Yanghao Hou, Theo F. J. Kraus, Maggie Lee, Friederike Liesche‐Starnecker, Anne Mc Leer, Linea Melchior, Michael Mittelbronn, Wolf C. Müller, Shalima S. Nair, Julia E. Neumann, Pitt Niehusmann, Nicole Pfarr, Torsten Pietsch, Marco Prinz, Markus Rechsteiner, Regina Reimann, Laveniya Satgunaseelan, Veronica Skarpeteig

Brain Pathology · 2026-07-15

DOI: 10.1111/bpa.70121 ↗
AbstractBibliografische Angaben

Abstract

Abstract BeadChip array‐based DNA methylation profiling has been recognized by the World Health Organization (WHO) as a key diagnostic tool for brain tumor classification. While its diagnostic utility has been well established, data on technical reproducibility, interlaboratory comparability, and data interpretation under real‐world diagnostic conditions remain limited. Bridging this gap, we here report the results of an international proficiency test using the Infinium MethylationEPIC v2.0 platform and the corresponding Brain Tumor Classifier version 12.8. Tissue slides of eight FFPE brain tumor samples, covering a representative range of CNS tumor entities, were distributed among 24 laboratories in 10 different countries. Participants were asked to report methylation classes and copy number variation (CNV) profiles. Pre‐array workflows were left to local procedures and results had to be submitted within 15 working days. Technical data reproducibility was high with a median pairwise beta‐value correlation of 0.99 (range 0.93–1.0). In general, participating centers generated high‐quality data, reflected by consistently low detection p ‐values (

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →