EUVIMEDEUVIMED entdecken
CrossrefInfokarte

In Vivo Comparison of Algorithms Estimating Left Ventricular Stroke Work From LVAD ‐Derived Pump Parameters

Moriz A. Habigt, Marc Hein, Mare Mechelinck, Frederic Olbrich, Maike Stemmler, Alexander Schulz, Barbara Hammer, Sebastian Billig

Artificial Organs · 2026-11-10

DOI: 10.1111/aor.70277 ↗
AbstractBibliografische Angaben

Abstract

ABSTRACT Background Accurate assessment of cardiac work during left ventricular assist device (LVAD) therapy is essential for patient management, device explantation timing, and adaptive control algorithm development. While invasive pressure–volume methods provide accurate work and contractility assessment, their clinical applicability is limited. Non‐invasive algorithms utilizing inherent pump parameters offer a promising alternative, yet no systematic comparison exists. Methods Six non‐invasive algorithms for estimating stroke work (SW) were compared in 22 healthy German Landrace pigs (48.9 ± 2.6 kg) with a Deltastream DP3 LVAD: maximal LVAD flow derivative, motor power–LV pressure relationship, pressure head–flow relationship, systolic fraction of pressure–flow area, and total/pulsatile components of pump current and flow. After isoflurane‐induced heart failure, four interventions were performed: preload reduction (inferior vena cava occlusion, n = 105), afterload increase (aortic balloon occlusion, n = 97), dobutamine infusion ( n = 21), and speed ramps ( n = 14). Linear multilevel modeling revealed significant main effects for algorithm ( χ 2 = 582.38), intervention type ( χ 2 = 73.77), and their interaction ( χ 2 = 324.80; all p < 0.001), explaining 54.04% of variability. Results The pressure head‐flow algorithm demonstrated consistently high correlations across interventions, though requiring semi‐invasive pressure measurements. The pump flow area algorithm performed robustly during preload, afterload, and speed ramps but failed to capture SW changes during dobutamine. The systolic fraction algorithm achieved the highest correlations during dobutamine but frequently failed mathematical optimization, limiting applicability. Conclusion No single algorithm performed optimally across all conditions, necessitating context‐specific selection. Pronounced inter‐individual variability underscores the importance of patient‐specific factors. These findings provide the first systematic comparison of non‐invasive SW algorithms during LVAD therapy, offering guidance for algorithm selection.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →