Diagnostic accuracy of qualitative gastric ultrasound assessment for detecting high gastric fluid volume in children: a prospective randomised study
Anaesthesia · 2025-06 · 80 (6) · 636-644
DOI: 10.1111/anae.16539 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Anaesthesia, online erschienen am 07.01.2025. Verfasst von Eloïse Cercueil und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesia and Intensive Care, Hospices Civils de Lyon, Femme Mère Enfant Hospital, Bron, France. Hauptthemen laut MEDLINE: Gastrointestinal Contents, Pyloric Antrum, Stomach. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
Introduction
The diagnostic accuracy of gastric ultrasound in children has not been assessed thoroughly. We aimed to determine the sensitivity and specificity in children of a qualitative ultrasound examination of the gastric antrum in the supine 45° semi‐recumbent position and a clinical algorithm for detecting a gastric fluid volume > 1.25 ml.kg ‐1 , reported to represent an ‘at‐risk stomach’ for pulmonary aspiration.
Methods
We conducted a prospective, observer‐blinded, randomised trial in healthy children fasted according to current pre‐operative guidelines. An initial ultrasound assessment of gastric contents ensured that the stomach was empty. Children then drank a specific volume of water (0; 0.6; 1; 1.25; 1.5; or 2 ml.kg ‐1 ). Gastric ultrasound was performed after 3 min of fluid ingestion, in children lying supine and then in the right lateral decubitus position, with the head of the bed elevated to 45° (semi‐recumbent). A clinical algorithm combining the qualitative assessment with calculation of gastric fluid volume was also completed. The sensitivity and specificity of the qualitative assessment in the supine semi‐recumbent position and the clinical algorithm for the diagnosis of gastric fluid volume > 1.25 ml.kg ‐1 were estimated.
Results
Ninety children, median (IQR [range]) age 7 (4.5–9 [1–10]) y, were studied. The sensitivity and specificity of the qualitative assessment for detecting gastric fluid volume > 1.25 ml.kg ‐1 were 75% (95%CI 58–88%) and 85% (95%CI 73–93%), respectively. The sensitivity and specificity of the clinical algorithm were 86% (95%CI 71–95%) and 78% (95%CI 64–88%), respectively.
Discussion
In order to achieve high sensitivity of gastric ultrasound for the diagnosis of fluid volume > 1.25 ml.kg ‐1 in children, qualitative ultrasound assessment of gastric antrum contents should be combined with calculation of gastric fluid volume when fluid contents are seen in the gastric antrum.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anaesthesia and Intensive Care, Hospices Civils de Lyon, Femme Mère Enfant Hospital, Bron, France.
- Research Unit APCSe VetAgro Sup UP 2021.A101-University of Lyon, Université Claude Bernard Lyon 1, Villeurbanne, France.
ORCID-Profile: Lionel Bouvet
Zitieren
APA
Cercueil, E., Henriet, A., Barbe, C., Santos Machado, G., & Bouvet, L. (2025). Diagnostic accuracy of qualitative gastric ultrasound assessment for detecting high gastric fluid volume in children: a prospective randomised study. Anaesthesia, 80(6), 636-644. https://doi.org/10.1111/anae.16539
Vancouver
Cercueil E, Henriet A, Barbe C, Santos Machado G, Bouvet L. Diagnostic accuracy of qualitative gastric ultrasound assessment for detecting high gastric fluid volume in children: a prospective randomised study. Anaesthesia. 2025;80(6):636-644. doi:10.1111/anae.16539
BibTeX
@article{Cercueil2025,
author = {Cercueil, Eloïse and Henriet, Anaïs and Barbe, Corwyn and Santos Machado, Guinter and Bouvet, Lionel},
title = {Diagnostic accuracy of qualitative gastric ultrasound assessment for detecting high gastric fluid volume in children: a prospective randomised study},
journal = {Anaesthesia},
year = {2025},
volume = {80},
number = {6},
pages = {636--644},
doi = {10.1111/anae.16539}
}