EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Automated Insulin Delivery in Pregnancies Complicated by Type 1 Diabetes: A Real World Observational Study of Available Systems

Stephanie L. Teasdale, Julian Pavey, Melissa Lee, Janelle C. Nisbet

Australian and New Zealand Journal of Obstetrics and Gynaecology · 2026-12 · 66 (6)

DOI: 10.1111/ajo.70198 ↗
AbstractBibliografische Angaben

Abstract

ABSTRACT Background Only one automated insulin delivery (AID) system is licensed in Australia for use in pregnancies complicated by Type 1 diabetes (T1D); however, some women using other AID systems have continued to use these ‘off‐label’ in pregnancy. Usage patterns from a single centre in Australia will be of interest to clinicians supporting women with T1D in pregnancy. Aims This is an observational study evaluating outcomes in women treated with different AID systems through a pregnancy cared for at a tertiary maternity centre. Materials and Methods All women using AID in one or more trimesters of pregnancy through a 3‐year study period are included in the reporting of glycaemic and insulin delivery measures in each trimester of pregnancy. All women using AID throughout the duration of a pregnancy within the study period are included in the reporting of birth outcomes. Results Four AID systems had been used during the study period, MiniMed with Smartguard, T:slim with Control IQ, YpsoMed with CamAPS and Omnipod with SmartAdjust. Small numbers of YpsoMed and Omnipod users precluded these from statistical analysis. Women using MiniMed and T:slim AID systems differed in terms of early HbA1c and smoking history with MiniMed users representing suboptimal pre‐pregnancy diabetes control. Use of continuous glucose monitoring (CGM) was additionally significantly lower for users of the MiniMed system. Median pregnancy‐specific time in range (pTIR) was above 62% for all systems by trimester 2 and above 64% for all systems by trimester 3 with no significant difference between MiniMed and T:slim systems. There was less pregnancy‐specific time below range (pTBR) and/or time well below range (pTWBR) for the MiniMed system in all trimesters compared with the T:slim system. Conclusions AID systems without the tight target considered necessary for pregnancy were still able to achieve good glycaemic outcomes.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →