Radiographic assessment of carpal conformation in the horse: Technique development and validation of the consistency of measurements
Anatomia, Histologia, Embryologia · 2021-03 · 50 (2) · 284-299
DOI: 10.1111/ahe.12627 ↗Kurz gefasst
Fachartikel in der Zeitschrift Anatomia, Histologia, Embryologia, online erschienen am 05.11.2020. Verfasst von Timothy A O Olusa und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Veterinary and Agricultural Sciences, University of Melbourne, Werribee, Vic., Australia. Hauptthemen laut MEDLINE: Carpal Bones, Horse Diseases. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: The University of Melbourne, Australia.
Abstract (Originalsprache)
Carpal conformation is often considered as a contributory factor to performance and lameness in the horse; however, few attempts have been made to objectively measure radiographic variations of carpal conformation in horses due to insufficient measurable carpal parameters. This pilot study used carpal radiographic images acquired from 10 cadaveric equine forelimbs transected at the antebrachial midshaft from 7 adult horses (7.2 ± 2.6 years), positioned at ‘zero lateromedial’ (ZLM) and ‘zero dorsopalmar’ (ZDP) views, to investigate the anatomy of the equine carpus and develop parameters that could be objectively used to assess carpal conformation in horses. Dorsal carpal angle (DCA: 176.61 ± 0.66º), distal radial slope carpal angle (DRSCA: 145.59 ± 2.19º), intermediate carpal bone proximal tuberosity‐radial angle (CiPxTRA: 115.69 ± 3.15º) and third carpal bone palmar facet angle (C3PalFCA: 84.43 ± 1.13º) were all developed from the ZLM view while medial carpal angle (MCA: 183.34 ± 1.02º), disto‐dorsal slope angle of the third carpal bone (C3DDSA: 8.27 ± 0.92º) and width ratio of distal radius to proximal metacarpus (WDR:WPM = 1.13±0.03) were 3 of the 10 parameters developed from the ZDP view. Easy to identify and measurable parameters will help to provide quantitative assessment of carpal conformation in the horse with potential of eliminating subjective observational variation errors between clinicians. These newly developed parameters will be useful in further studies to measure variations in the conformation of the equine carpus in live horses and comparison between subjective visual assessment and objective radiographic evaluation methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Veterinary and Agricultural Sciences, University of Melbourne, Werribee, Vic., Australia.
ORCID-Profile: Timothy A O Olusa
Förderung
- The University of Melbourne, Australia
Zitieren
APA
Olusa, T. A. O., Ismail, S. M. Y., Murray, C. M., & Davies, H. M. S. (2021). Radiographic assessment of carpal conformation in the horse: Technique development and validation of the consistency of measurements. Anatomia, Histologia, Embryologia, 50(2), 284-299. https://doi.org/10.1111/ahe.12627
Vancouver
Olusa TAO, Ismail SMY, Murray CM, Davies HMS. Radiographic assessment of carpal conformation in the horse: Technique development and validation of the consistency of measurements. Anatomia, Histologia, Embryologia. 2021;50(2):284-299. doi:10.1111/ahe.12627
BibTeX
@article{Olusa2021,
author = {Olusa, Timothy A O and Ismail, Sa'ad M Y and Murray, Christina M and Davies, Helen M S},
title = {Radiographic assessment of carpal conformation in the horse: Technique development and validation of the consistency of measurements},
journal = {Anatomia, Histologia, Embryologia},
year = {2021},
volume = {50},
number = {2},
pages = {284--299},
doi = {10.1111/ahe.12627}
}
EUVIMED