EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Novel co-axial, disposable, low-cost 3D printed videolaryngoscopes for patients with COVID-19: a manikin study

Laura Gorman, Andrew N. Dickson, Myles Monaghan, Frank Vaughan, Brian Murphy, Denis P. Dowling, Conan McCaul, James F.X. Jones

European Journal of Anaesthesiology Intensive Care · 2023

DOI: 10.1097/ea9.0000000000000015 ↗
AbstractBibliografische Angaben

Abstract

BACKGROUND COVID-19 continues to present challenges to both patient management and the protection of the airway management team involved, in particular in resource-constrained low-income countries. Among the most concerning complications in affected patients is rapid hypoxemic respiratory failure requiring tracheal intubation and mechanical ventilation. Videolaryngoscopy without peri-intubation oxygenation is the recommended approach in COVID-19 patients. However, the absence of peri-intubation oxygenation during intubation attempts can lead to hypoxia, and result in life-threatening complications in already critically ill patients. OBJECTIVE To develop low-cost disposable 3D printed videolaryngoscope designs with integrated channels for oxygen, suction, WIFI-enabled camera and tracheal tube channels, as well as a flexible transparent barrier anchor to offer optional additional protection to the user and airway management team. DESIGN A manikin study. SETTING AND PARTICIPANTS Three experienced consultant anaesthetists in the Mater Misericordiae University Hospital, Dublin, Ireland. MAIN OUTCOME MEASURES To generate novel co-axial videolaryngoscopes that meet International Standards, ISO7376 : 2020 standards for anaesthetic and respiratory equipment (laryngoscopes for tracheal intubation), and to demonstrate successful tracheal intubation of a manikin trainer in a range of configurations (‘easy’ to ‘difficult’) in accordance with the Cormack-Lehane grading of laryngeal view. RESULTS Final design prototypes met the minimum criteria for strength and rigidity according to ISO7376 : 2020, including blade tip displacement under load (65 N and 150 N). Preliminary validation has demonstrated successful tracheal intubation of a manikin trainer in all configurations including ‘difficult’ (Cormack-Lehane Grade 3 view). CONCLUSIONS This low-cost, rapid in-house manufacture could offer a mitigation of supply chain disruptions that can arise during global pandemics. Furthermore, it could offer a low-cost solution in low-income countries where there is an infection risk caused by re-using most current videolaryngoscopes requiring sterilisation before re-use, as well as limitations in the availability of personal protective equipment.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →