EUVIMEDEUVIMED entdecken
Crossref

Cardiac computed tomography angiography with and without bolus tracking methods in infants with congenital heart disease

Takayuki Yoshiura iD, Takanori Masuda iD, Masahiro Tahara iD, Yukie Kobayashi, Yukari Kikuhara, Toru Ishibashi iD, Haruki Nonaka, Takayuki Oku iD, Tomoyasu Sato iD, Yoshinori Funama

Radiation Protection Dosimetry · 02.03.2024 · 200 (3) · 251-258

DOI: 10.1093/rpd/ncad295 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 12.12.2023. Verfasst von Takayuki Yoshiura und 9 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Health Sciences, Kumamoto University, 4-24-1 Kuhonji, Kumamoto, 862-0976, Japan. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Heart Defects, Congenital. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The study investigated radiation dose, vascular computed tomography (CT) enhancement and image quality of cardiac computed tomography angiography (CCTA) with and without bolus tracking (BT) methods in infants with congenital heart disease (CHD). The volume CT dose index (CTDIvol) and dose length product (DLP) were recorded for all CT scans, and the effective dose was obtained using a conversion factors. The CT number for the ascending aorta (AO) and pulmonary artery (PA), image noise of muscle tissue and contrast-to-noise ratio (CNR) were measured and calculated. The median values in the groups with and without BT were 2.20 mGy versus 0.44 mGy for CTDIvol, 8.10 mGy·cm versus 6.20 mGy·cm for DLP, and 0.66 mSv versus 0.51 mSv for effective dose (p < 0.001). There were no statistical differences in vascular CT enhancement, image noise, and CNR. CCTA without BT methods can reduce the radiation dose while maintaining vascular CT enhancement and image quality compared to CCTA with BT methods.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computed Tomography AngiographyHeart Defects, CongenitalInfantHumansTomography, X-Ray ComputedAngiographyRadionuclide ImagingRadiation Dosage

Autor:innen und Institutionen

  • Graduate School of Health Sciences, Kumamoto University, 4-24-1 Kuhonji, Kumamoto, 862-0976, Japan.
  • Department of Medical Technology, Tsuchiya General Hospital, 3-30 Nakajima-cho, Hiroshima, 730-8655, Japan.
  • Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-City, Okayama, 701-0193, Japan.
  • Hiroshima Central Street Children's Clinic, 7-1 Mikawa-cho, Hiroshima, 730-0029, Japan.
  • Department of Medical Radiation Sciences, Faculty of Life Sciences, Kumamoto University, 4-24-1 Kuhonji, Kumamoto, 862-0976, Japan.

ORCID-Profile: Takayuki Yoshiura, Takanori Masuda, Masahiro Tahara, Toru Ishibashi, Takayuki Oku, Tomoyasu Sato

Zitieren

APA

Yoshiura, T., Masuda, T., Tahara, M., Kobayashi, Y., Kikuhara, Y., Ishibashi, T., Nonaka, H., Oku, T., Sato, T., & Funama, Y. (2024). Cardiac computed tomography angiography with and without bolus tracking methods in infants with congenital heart disease. Radiation Protection Dosimetry, 200(3), 251-258. https://doi.org/10.1093/rpd/ncad295

Vancouver

Yoshiura T, Masuda T, Tahara M, Kobayashi Y, Kikuhara Y, Ishibashi T, et al. Cardiac computed tomography angiography with and without bolus tracking methods in infants with congenital heart disease. Radiation Protection Dosimetry. 2024;200(3):251-258. doi:10.1093/rpd/ncad295

BibTeX
@article{Yoshiura2024,
  author = {Yoshiura, Takayuki and Masuda, Takanori and Tahara, Masahiro and Kobayashi, Yukie and Kikuhara, Yukari and Ishibashi, Toru and Nonaka, Haruki and Oku, Takayuki and Sato, Tomoyasu and Funama, Yoshinori},
  title = {Cardiac computed tomography angiography with and without bolus tracking methods in infants with congenital heart disease},
  journal = {Radiation Protection Dosimetry},
  year = {2024},
  volume = {200},
  number = {3},
  pages = {251--258},
  doi = {10.1093/rpd/ncad295}
}
Kostenlos starten →