EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Improved prostate diffusion imaging using deep learning denoising and phase correction with ultra-high-density coil array

Sherry S Huang, Xinzeng Wang, Patricia Lan, Milica Medved, Nurullah Kaya, Clyve K Follante, Yunjeong Stickle, Jonathan Taylor, Ambereen Yousuf, Roger Engelmann, Fraser J L Robb, Arnaud Guidon, Grace Lee, Aytekin Oto

Radiology Advances · 2026-03-03 · 3 (2)

DOI: 10.1093/radadv/umag019 ↗
AbstractBibliografische Angaben

Abstract

Abstract Background MR diffusion-weighted imaging (DWI), especially at high b-value, is a key acquisition to help identify clinically significant prostate cancer; however, it suffers from low signal-to-noise ratio (SNR), high noise floor, and susceptibility artifact. Purpose To demonstrate the feasibility of improving DWI quality using a novel 50-channel pelvic coil in conjunction with a deep learning (DL)-based phase correction and a DL-denoising algorithm. Methods In this prospective, single-center study, 24 consecutive men referred for prostate multiparametric MRI over 16 months were enrolled (age 47–79 years; mean, 68.1 years). Axial T2-weighted images and DWI were obtained using a prototype 50‑channel coil and standard clinical phased array (3 T Architect, GE HealthCare, USA). The DWI acquisitions were reconstructed with the vendor’s deep learning denoising algorithm (ARDL). The same raw data were reconstructed offline using an investigational DL Phase Correction algorithm with ARDL (DLPC+ARDL). Two independent readers scored DWI and ADC series using 4 qualitative criteria. SNR and contrast-to-noise ratio (CNR) were measured on b = 1500 s/mm2 images. Combined reader scores were compared using the Wilcoxon matched‑pairs signed‑rank test, inter‑reader variability was assessed using Cohen’s κ, and quantitative SNR/CNR values were compared using 2‑tailed paired t‑tests. Results Twenty men were analyzable for qualitative and 18 for quantitative metrics (reported as mean ± SD). 50‑channel pelvic coil with DLPC+ARDL produced the highest SNR (99.70 ± 28.50) and CNR (91.68 ± 44.39), exceeding 50‑channel with ARDL alone (SNR 56.44 ± 28.50; CNR 51.11 ± 28.67), 30‑channel anterior array with ARDL (SNR 31.41 ± 13.18; CNR 26.26 ± 13.52), and DLPC + ARDL (SNR 49.4 ± 18.6; CNR 44.7 ± 18.3) (all P < .0001). Reader scores favored DLPC+ARDL in prostate border definition, peripheral/transition zone distinction, lesion conspicuity, and confidence of extraprostatic extension (all P values for DWI at b = 1500 s/mm2 < 0.0001; synthetic DWI at b = 2000 s/mm2: P = 7.5 × 10−7–0.01). Inter‑reader agreement was fair for acquired DWI (quadratic‑weighted κ = 0.34) and lower for synthetic DWI (κ = 0.19). Conclusion DWI images acquired using the 50‑channel pelvic coil and reconstructed with the DLPC + ARDL pipeline yield the highest image quality compared to ARDL only pipeline and to all 30-channel coil imaging.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →