EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Imaging of the inferior alveolar nerve using dental-dedicated MRI at 0.55 T: Comparison of a deep learning-based accelerated sequence with a conventional sequence

Maximilian Hinsen, Markus Kopp, Martin Zeilinger, Claudius S Mathy, Michael Uder, Andreas Greiser, Manuel Weber, Ines Willershausen, Konstantin Hellwig

Dentomaxillofacial Radiology · 2026-10-29

DOI: 10.1093/dmfr/twag068 ↗
AbstractBibliografische Angaben

Abstract

Abstract Objectives The aim of this study was to investigate the feasibility of low-field dental MRI in the evaluation of the inferior alveolar nerve (IAN) and the acceleration of image acquisition with a deep learning (DL)-based sequence. Therefore, overall image quality (OIQ), image artefacts and delineation of the IAN were investigated. Methods In this single-centre retrospective study, we enrolled 39 patients who underwent dental MRI using a dedicated dental coil on a 0.55 T MRI system. A conventional T1-weighted gradient-echo 3D sequence and a T1-weighted gradient-echo 3D sequence with advanced DL-based reconstruction were acquired. Both sequences were evaluated for OIQ, image artefacts in and conspicuity of the IAN using a Likert scale from 1 to 5. Interrater agreement was assessed using weighted Cohen’s κ coefficients. As quantitative measurements, the apparent signal-to-noise ratio (aSNR) and the diameter of the IAN were determined. Results Thirty-three examinations were included, OIQ was rated higher for the accelerated sequence compared with the conventional sequence for both readers (p < 0.01). Image artefacts were lower in the accelerated sequence for both readers (p < 0.001). Accordingly, the delineation of the IAN was improved for both sides (p < 0.001) in the accelerated sequence. Interrater agreement between readers was substantial/good to almost perfect/excellent across all measures. aSNR was increased in the accelerated sequence (p < 0.001), whereas IAN diameter did not differ. Conclusions This study demonstrates that a DL-accelerated T1-weighted gradient-echo 3D sequence for dental-dedicated MRI is feasible for imaging of the IAN with improved image quality while reducing acquisition time by 50%. Advances in Knowledge Reduction of scan time and superior image quality could help establish dental-dedicated MRI as a radiation-free alternative for dentomaxillofacial imaging.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →