EUVIMEDEUVIMED entdecken
CrossrefInfokarte

An in-silico simulation study to generate computed tomography images from ultrasound data by using deep learning techniques

Anatol A Aicher, Davide Cester, Alexander Martin, Karolina Pawlus, Florian A Huber, Thomas Frauenfelder, Catherine Paverd

BJR|Artificial Intelligence · 2025

DOI: 10.1093/bjrai/ubaf005 ↗
AbstractBibliografische Angaben

Abstract

Abstract Objectives Ultrasound has low sensitivity in parenchymal lesion detection compared to contrast-enhanced computed tomography (CT). In this proof-of-concept-study, we investigate whether raw ultrasound data can be used to generate CT-like images using deep learning models in order to enhance lesion detection. Methods The k-wave ultrasound and Astra CT simulation toolkits were used to generate 2 datasets (1000 samples each) from simulated phantoms with up to 3 inclusions. The pix2pix conditional Generative adversarial network (cGAN) was trained on 800 samples per dataset, reserving the remainder for testing. Outputs were evaluated using generalized contrast-to-noise ratio (gCNR) and Structural Similarity Index (SSIM). Segmentation of B-mode alone versus B-mode with model-generated CT overlay was performed by 2 radiologists (1 board-certified and 1 resident) and both their performance and inter-observer agreement were evaluated using the Jaccard Index. Results Model-generated CT-like images exhibited significantly improved gCNR (0.574±0.210 to 0.873±0.163) and SSIM (0.808±0.092 to 0.912±0.062) depending on phantom and inclusion type. Computed tomography-like images sometimes highlighted lesions otherwise undetectable in B-mode. The Jaccard index for 100 test samples improved significantly when segmenting Machine-Learning-augmented B-Mode compared with B-Mode images alone (0.58±0.18 to 0.69±0.16), depending on dataset and radiologist. Inter-observer agreement also improved significantly (0.74±0.18 to 0.85±0.07 for 1 dataset). Conclusions Deep learning models can effectively translate ultrasound data into CT-like images, improving quality and inter-observer agreement, and enhancing lesion detectability, for example, by alleviating shadowing artefacts. Advances in knowledge Generating CT-like images using raw ultrasound RF data as input to a cGAN model results in a significant improvement in lesion detectability by, for example, alleviating acoustic shadowing. With a cGAN architecture, even relatively small datasets can successfully generate CT-like images that improve lesion detectability.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →