EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Experimental feasibility study of proton therapy range verification by a digital tracking calorimeter prototype

Alexander Schilling, Johan Alme, Gergely Gábor Barnaföldi, Gábor Bíró, Tea Bodova, Illia Borshchov, Vyacheslav Borshchov, Anthony van den Brink, Lattawat Charoonratana, Bence Dudás, Gregory Feofilov, Nicolas R Gauger, Håvard Helstrup, Sergey Igolkin, Jacob G Johansen, Zsófia Jólesz, Ralf Keidel, Thitayawat Khumwong, Chinorat Kobdaj, Tobias Kortus, Natthawut Laojamnongwong, Odd Harald Odland, Gábor Papp, Thomas Peitzmann, Helge Egil Seime Pettersen, Maksym Protsenko, Attiq Ur Rehman, Matthias Richter, Narongrit Ritjoho, Dieter Röhrich, Hira Sharif, Tawanchat Simantathammakul, Ihor Tymchuk, Kjetil Ullaland, Shiming Yang, Jie Yi

Physics in Medicine & Biology · 2026-11-14 · 71 (21) · 215023

DOI: 10.1088/1361-6560/aebb8a ↗
AbstractBibliografische Angaben

Abstract

Abstract Objective. Uncertainties in the proton range remain an important challenge in proton therapy. In-situ range verification (RV) techniques can be used to ensure the Bragg peak depth in the patient matches the treatment plan. Various such methods are under investigation, utilizing the signal from secondary radiation caused by proton interactions with the patient. This study experimentally investigates the feasibility of using a silicon-pixel-based sampling calorimeter for RV through the detection of secondary photons and neutrons. Approach. The proton RV capability of a sampling calorimeter based on monolithic active pixel sensors was tested both theoretically and experimentally. We theoretically investigate the plausibility of the planned sampling calorimeter to pick up a signal from the neutral secondary particles distal to the patient. Then, a smaller prototype pixel telescope was constructed to verify our theoretical findings experimentally by placing it behind a water tank irradiated by a medical proton beam with various energies in the range of 100–200 MeV at the Danish Center for Particle Therapy, Aarhus, Denmark. Main results. We find that the aluminum used as absorbers between sensitive layers in the calorimeter serves as a converter for prompt gammas and neutrons. The combined detection efficiency ranges between 5.8 ⋅ 10 − 5 and 2.7 ⋅ 10 − 3 detector hits per primary proton for beam energies between 50 and 200 MeV. Irradiation of the water phantom leads to a signal in our detector, which is well-correlated with the nominal beam energy. A simulation-based model using only the number of hits per proton can predict the beam energy, acting as a proxy for proton range in a homogeneous target, down to a root mean squared error of 1.34 MeV. Significance. This study marks a promising step towards utilizing a tracking calorimeter designed for proton computed tomography for the secondary application of proton therapy RV without additional hardware costs.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →