EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Laboratory Monitoring of UFH in Different Settings (DEXHEP Study): Association between Anti-Xa Levels, Platelet Factor 4 (PF4) Plasma Levels and Dextran Sulfate

Philippe Savard, Emmanuel Curis, Isabelle Gouin-Thibault, Marie Toussaint-Hacquard, Céline Delassasseigne, Anne Bauters, Claire Flaujac, Valérie Eschwège, Christine Mouton, Thomas Lecompte, Emmanuel de Maistre, Dominique Lasne, Virginie Siguret

Thrombosis and Haemostasis · 2026-11 · 126 (11) · 1096-1104

DOI: 10.1055/a-2749-6046 ↗
AbstractBibliografische Angaben

Abstract

Abstract Chromogenic anti-Xa assay is currently used in the management of patients on unfractionated heparin (UFH). It has been shown that inter-assay variability in anti-Xa levels can be explained in part by the presence or absence of dextran sulfate (DXS) in the reagents. DXS has the ability to dissociate UFH from neutralizing proteins, including platelet factor 4 (PF4). Investigate whether PF4 plasma levels along with the presence/absence of DXS in anti-Xa reagents are associated with variations in UFH anti-Xa levels in different clinical situations. In the prospective multicenter study DEXHEP-NCT04700670, critically ill patients on UFH therapy (four groups) were recruited. Blood was collected into citrate and CTAD tubes. Chromogenic anti-Xa levels were assessed using seven reagent/analyzer combinations including two without DXS. Plasma PF4 was measured by ELISA (Zymutest-PF4-Hyphen-Biomed). A total of 144 patients were analyzed: average PF4 levels in citrate plasma samples were consistently higher than in CTAD ones (206 vs. 46 ng/mL, p < 10−4), regardless of the patient group. Using a linear mixed-effect model, we found a significant effect of both DXS and PF4 on anti-Xa level, with a significant interaction term (p < 10−4). Considering the 0.3 to 0.7 IU/mL therapeutic range, agreement between anti-Xa values (Liquid-anti-Xa/DXS-free vs. Biophen-LRT/DXS) was observed in roughly two-thirds of the patients. PF4 levels slightly affects anti-Xa levels, the use of CTAD tubes minimizing the effect. However, PF4 levels do not fully explain the differences of anti-Xa levels observed in the presence or absence of DXS, which has a greater effect. Anti-Xa assays require better standardization.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →