Kurz gefasst

Übersichtsarbeit in der Zeitschrift RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, erschienen am 01.05.2025. Verfasst von Muhammad Taha Hagar und 14 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, United States. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Cardiovascular Diseases. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 51 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Since the approval of the first dual-source photon-counting detector CT (PCD-CT) in the fall of 2021, significant insights have been gained in its application for cardiovascular imaging. This review aims to provide a comprehensive overview of the current state of knowledge and the growing body of research literature, illustrating innovative applications and perspectives through case examples. We conducted a structured literature review, identifying relevant studies via Google Scholar and PubMed, using the keywords “photon-counting detector”, “cardiovascular CT”, “cardiac CT”, and “ultra-high-resolution CT”. We analyzed studies published since January 2015. Additionally, we integrated our own clinical experiences and case examples. In addition to the well-known benefit of increased temporal resolution offered by dual-source scanners, dual-source PCD-CT provides three key advantages: 1) Optimized geometric dose efficiency with an improved contrast-to-noise ratio, 2) intrinsic spectral sensitivity, and 3) the ability for ultrahigh-resolution CT. This technology enables improved image quality or radiation dose reduction in established cardiovascular protocols. Its use in non-invasive cardiac diagnostics for obese patients, those with a high plaque burden, or after stent implantation appears technically feasible, potentially expanding the scope of CT. The spectral sensitivity also allows tailored image acquisition, reducing metallic artifacts and contrast agent doses in patients with renal impairment. Early studies and clinical experience support these potential applications of PCD-CT in cardiovascular diagnostics, suggesting workflow optimization and improved patient management. However, challenges remain, including high costs, large data volumes, somewhat longer reconstruction times, and technical difficulties in combining spectral sensitivity with ultra-high resolution. Prospective randomized studies with clinical endpoints are lacking to confirm the clear advantage over conventional scanners. Future research should focus on endpoint-based studies and robust cost-benefit analyses to evaluate the potential of this technology and facilitate its evidence-based integration in clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedCardiovascular DiseasesHumansPhotonsRadiation Dosage

Autor:innen und Institutionen

  • Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, United States.
  • Department of Diagnostic and Interventional Radiology, University of Freiburg Faculty of Medicine, Freiburg, Germany.
  • Department of Radiology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.
  • Computed Tomography, Siemens Healthineers AG, Forchheim, Germany.
  • Department of Diagnostic and Interventional Radiology, University of Bonn, Bonn, Germany.
  • Department of Medical Surgical Sciences and Translational Medicine, University of Rome La Sapienza, Rome, Italy.

ORCID-Profile: Muhammad Taha Hagar, Christopher Schuppert

Zitieren

APA

Hagar, M. T., Schlett, C. L., Oechsner, T., Varga-Szemes, A., Emrich, T., Chen, X. Y., Kravchenko, D., Tremamunno, G., Vecsey-Nagy, M., Molina-Fuentes, M. F., Krauss, T., Taron, J., Schuppert, C., Bamberg, F., & Soschynski, M. (2025). Photon-Counting Detector CT: Advances and Clinical Applications in Cardiovascular Imaging. RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 197(05), 509-517. https://doi.org/10.1055/a-2452-0288

Vancouver

Hagar MT, Schlett CL, Oechsner T, Varga-Szemes A, Emrich T, Chen XY, et al. Photon-Counting Detector CT: Advances and Clinical Applications in Cardiovascular Imaging. RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren. 2025;197(05):509-517. doi:10.1055/a-2452-0288

BibTeX
@article{Hagar2025,
  author = {Hagar, Muhammad Taha and Schlett, Christopher L and Oechsner, Tim and Varga-Szemes, Akos and Emrich, Tilman and Chen, Xiao Yan and Kravchenko, Dmitrij and Tremamunno, Giuseppe and Vecsey-Nagy, Milán and Molina-Fuentes, Moises Felipe and Krauss, Tobias and Taron, Jana and Schuppert, Christopher and Bamberg, Fabian and Soschynski, Martin},
  title = {Photon-Counting Detector CT: Advances and Clinical Applications in Cardiovascular Imaging},
  journal = {RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren},
  year = {2025},
  volume = {197},
  number = {05},
  pages = {509--517},
  doi = {10.1055/a-2452-0288}
}
Kostenlos starten →