EUVIMEDEUVIMED entdecken
Crossref

The Correlation between Fetal Monitor Decelerations Area and Neonatal Cord pH among Preeclamptic parturient: an Automated Approach to a Clinical Challenge

Reut Rotem iD, Ella Theodor, Ayala Hirsch, Misgav Rottenstreich iD, Shimrit Y Salem, Adi Y Weintraub

American Journal of Perinatology · 01.05.2024 · 41 (S 01 S 01) · e3133-e3139

DOI: 10.1055/a-2196-6469 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Perinatology, erschienen am 01.05.2024. Verfasst von Reut Rotem und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, Shaare Zedek Medical Center, Jerusalem, Israel. Hauptthemen laut MEDLINE: Pre-Eclampsia, Fetal Blood. Die Arbeit nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To examine whether a correlation exists between electronic fetal monitoring (EFM) in the final 120 minute prior to delivery and neonatal cord blood pH among parturients with preeclampsia. Study Design A retrospective cohort study of parturients with term and near-term preeclampsia who delivered at Soroka University Medical Center between 2013 and 2020 was conducted. EFM tracings, demographical data, and obstetrical outcomes were retrieved from the patients' electronic medical records. Using MATLAB program, area under the curve (AUC) measurements were applied. Correlation was calculated using the Spearman's correlation coefficient.

Results

EFM of 88 parturients with preeclampsia were assessed. A significant negative correlation was demonstrated between cord blood pH and the decelerations AUC, total decelerations duration, and deceleration depth. No correlation was demonstrated between area over the curve (acceleration) and cord blood pH. In a multivariate linear regression, total deceleration AUC was found independently negatively associated with cord blood pH (beta = −0.264, p = 0.011) controlling for second stage of labor duration and induction of labor.

Conclusion

Among parturients with preeclampsia, EFM indices may assist in the diagnosis of fetal acidemia. Further studies are needed to strengthen and establish the use of electronic EFM in the management of labor and delivery. Key Points

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pre-EclampsiaFetal BloodHumansFemalePregnancyRetrospective StudiesHydrogen-Ion ConcentrationAdultInfant, NewbornCardiotocographyAcidosisFetal MonitoringArea Under CurveDecelerationHeart Rate, FetalLinear Models

Autor:innen und Institutionen

  • Department of Obstetrics and Gynecology, Shaare Zedek Medical Center, Jerusalem, Israel.
  • Department of Obstetrics and Gynecology, Faculty of Health Sciences, Soroka University Medical Center, Ben-Gurion University of the Negev, Beer-Sheva, Israel.

ORCID-Profile: Reut Rotem, Misgav Rottenstreich

Zitieren

APA

Rotem, R., Theodor, E., Hirsch, A., Rottenstreich, M., Salem, S. Y., & Weintraub, A. Y. (2024). The Correlation between Fetal Monitor Decelerations Area and Neonatal Cord pH among Preeclamptic parturient: an Automated Approach to a Clinical Challenge. American Journal of Perinatology, 41(S 01 S 01), e3133-e3139. https://doi.org/10.1055/a-2196-6469

Vancouver

Rotem R, Theodor E, Hirsch A, Rottenstreich M, Salem SY, Weintraub AY. The Correlation between Fetal Monitor Decelerations Area and Neonatal Cord pH among Preeclamptic parturient: an Automated Approach to a Clinical Challenge. American Journal of Perinatology. 2024;41(S 01 S 01):e3133-e3139. doi:10.1055/a-2196-6469

BibTeX
@article{Rotem2024,
  author = {Rotem, Reut and Theodor, Ella and Hirsch, Ayala and Rottenstreich, Misgav and Salem, Shimrit Y and Weintraub, Adi Y},
  title = {The Correlation between Fetal Monitor Decelerations Area and Neonatal Cord pH among Preeclamptic parturient: an Automated Approach to a Clinical Challenge},
  journal = {American Journal of Perinatology},
  year = {2024},
  volume = {41},
  number = {S 01 S 01},
  pages = {e3133--e3139},
  doi = {10.1055/a-2196-6469}
}
Kostenlos starten →