EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Quantitative Semisolid Magnetization Transfer and Relayed Nuclear Overhauser Effect Imaging in a Multiple Sclerosis Mouse Model Using Deep Magnetic Resonance Fingerprinting

Ruth Ben Chaim, Michal Rivlin, Or Perlman

Chemical & Biomedical Imaging · 08.11.2026

DOI: 10.1021/cbmi.6c00179 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Chemical & Biomedical Imaging, online erschienen am 08.11.2026. Verfasst von Ruth Ben Chaim und 2 weiteren Autor:innen. Die Arbeit nennt 73 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: HORIZON EUROPE European Research Council, Israel Science Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magnetic resonance imaging (MRI) is the imaging modality of choice for the diagnosis, characterization, and monitoring of multiple sclerosis (MS). Nevertheless, the contrasts manifested by MS lesions often overlap with those of other pathological conditions, highlighting the need for additional disease biomarkers. In addition, while saturation transfer (ST) MRI provides molecular information associated with myelin, proteins, and lipids, quantifying the underlying proton exchange parameters remains challenging. Here, we describe a strategy that extends and modifies AI-boosted ST magnetic resonance fingerprinting (MRF) imaging at 7T. This approach was used to quantify the dynamics of the semisolid magnetization transfer (MT) and the aliphatic relayed nuclear Overhauser effect (rNOE at −3.5 ppm and −1.6 ppm relative to water) in a longitudinal cuprizone MS mouse model (n = 12). In lipid phantoms, the reconstructed proton volume fractions were strongly correlated with known lipid concentrations across all three proton pools (r > 0.96, p < 0.001). In vivo, semisolid MT and rNOE proton volume fractions in the corpus callosum demonstrated a significant decrease (p < 0.01) as early as week 4 of cuprizone feeding, preceding changes detected by conventional water relaxometry. ST-MRF based biomarkers were in agreement with histological findings. Overall, our results demonstrate the feasibility of rapid, multipool ST-MRF quantification for MS characterization.

Förderung

  • HORIZON EUROPE European Research Council
  • Israel Science Foundation

Zitieren

APA

Chaim, R. B., Rivlin, M., & Perlman, O. (2026). Quantitative Semisolid Magnetization Transfer and Relayed Nuclear Overhauser Effect Imaging in a Multiple Sclerosis Mouse Model Using Deep Magnetic Resonance Fingerprinting. Chemical & Biomedical Imaging. https://doi.org/10.1021/cbmi.6c00179

Vancouver

Chaim RB, Rivlin M, Perlman O. Quantitative Semisolid Magnetization Transfer and Relayed Nuclear Overhauser Effect Imaging in a Multiple Sclerosis Mouse Model Using Deep Magnetic Resonance Fingerprinting. Chemical & Biomedical Imaging. 2026. doi:10.1021/cbmi.6c00179

BibTeX
@article{Chaim2026,
  author = {Chaim, Ruth Ben and Rivlin, Michal and Perlman, Or},
  title = {Quantitative Semisolid Magnetization Transfer and Relayed Nuclear Overhauser Effect Imaging in a Multiple Sclerosis Mouse Model Using Deep Magnetic Resonance Fingerprinting},
  journal = {Chemical & Biomedical Imaging},
  year = {2026},
  doi = {10.1021/cbmi.6c00179}
}
Kostenlos starten →