EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Simulation of coronary fractional flow reserve and whole-cycle flow based on optical coherence tomography in individual patients with coronary artery disease

Niels Thue Olsen, Kaining Sheng

The International Journal of Cardiovascular Imaging · 2024

DOI: 10.1007/s10554-024-03151-6 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift The International Journal of Cardiovascular Imaging, 2024. Verfasst von Niels Thue Olsen und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Copenhagen University Hospital - Herlev and Gentofte, Copenhagen, Denmark. niels.thue.olsen@regionh.dk. Hauptthemen laut MEDLINE: Fractional Flow Reserve, Myocardial, Tomography, Optical Coherence, Predictive Value of Tests, Coronary Angiography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Novo Nordisk Fonden, Copenhagen University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Computer simulations of coronary fractional flow reserve (FFR) based on coronary imaging have emerged as an attractive alternative to invasive measurements. However, most methods are proprietary and employ non-physiological assumptions. Our aims were to develop and validate a physiologically realistic open-source simulation model for coronary flow, and to use this model to predict FFR based on intracoronary optical coherence tomography (OCT) data in individual patients. We included patients undergoing elective coronary angiography with angiographic borderline coronary stenosis. Invasive measurements of coronary hyperemic pressure and absolute flow and OCT imaging were performed. A computer model of coronary flow incorporating pulsatile flow and the effect of left ventricular contraction was developed and calibrated, and patient-specific flow simulation was performed. Forty-eight coronary arteries from 41 patients were included in the analysis. Average FFR was 0.79 ± 0.14, and 50% had FFR ≤ 0.80. Correlation between simulated and measured FFR was high (r = 0.83, p < 0.001). Average difference between simulated FFR and observed FFR in individual patients was − 0.009 ± 0.076. Overall diagnostic accuracy for simulated FFR ≤ 0.80 in predicting observed FFR ≤ 0.80 was 0.88 (0.75–0.95) with sensitivity 0.79 (0.58–0.93) and specificity 0.96 (0.79–1.00). The positive predictive value was 0.95 (0.75–1.00) and the negative predictive value was 0.82 (0.63–0.94). In conclusion, realistic simulations of whole-cycle coronary flow can be produced based on intracoronary OCT data with a new, computationally simple simulation model. Simulated FFR had moderate numerical agreement with observed FFR and a good diagnostic accuracy for predicting hemodynamic significance of coronary stenoses.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fractional Flow Reserve, MyocardialTomography, Optical CoherencePredictive Value of TestsCoronary AngiographyCoronary VesselsModels, CardiovascularPatient-Specific ModelingCoronary StenosisCoronary Artery DiseaseHumansFemaleMaleMiddle AgedAgedReproducibility of ResultsBlood Flow VelocityPulsatile FlowHyperemiaCardiac CatheterizationVentricular Function, LeftSeverity of Illness IndexComputer Simulation

Stichwörter der Autor:innen

Computer simulationCoronary artery diseaseCoronary physiologyFractional flow reserveMicrovascular function

Autor:innen und Institutionen

  • Department of Cardiology, Copenhagen University Hospital - Herlev and Gentofte, Copenhagen, Denmark. niels.thue.olsen@regionh.dk.
  • Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark. niels.thue.olsen@regionh.dk.
  • Department of Cardiology, Copenhagen University Hospital - Herlev and Gentofte, Copenhagen, Denmark.
  • Department of Radiology, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark.

Förderung

  • Novo Nordisk Fonden
  • Copenhagen University

Zitieren

APA

Olsen, N. T., & Sheng, K. (2024). Simulation of coronary fractional flow reserve and whole-cycle flow based on optical coherence tomography in individual patients with coronary artery disease. The International Journal of Cardiovascular Imaging. https://doi.org/10.1007/s10554-024-03151-6

Vancouver

Olsen NT, Sheng K. Simulation of coronary fractional flow reserve and whole-cycle flow based on optical coherence tomography in individual patients with coronary artery disease. The International Journal of Cardiovascular Imaging. 2024. doi:10.1007/s10554-024-03151-6

BibTeX
@article{Olsen2024,
  author = {Olsen, Niels Thue and Sheng, Kaining},
  title = {Simulation of coronary fractional flow reserve and whole-cycle flow based on optical coherence tomography in individual patients with coronary artery disease},
  journal = {The International Journal of Cardiovascular Imaging},
  year = {2024},
  doi = {10.1007/s10554-024-03151-6}
}
Kostenlos starten →