EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Combined cartilage thickness and mechanical property mismatch drives local strain amplification at the patellar osteochondral allograft interface

Michael A. Hernández Lamberty, John A. Grant, Ellen M. Arruda, Rhima M. Coleman

Biomechanics and Modeling in Mechanobiology · 2026-10 · 25 (5)

DOI: 10.1007/s10237-026-02128-9 ↗
AbstractBibliografische Angaben

Abstract

Abstract Patellar osteochondral allograft (OCA) transplantation treats focal cartilage defects, but donor-recipient cartilage thickness and mechanical compatibility are not routinely quantified during graft selection. This idealized computational study evaluated associations of donor-to-recipient ( D / R ) thickness ratio, absolute stiffness, stiffness contrast, and depth-dependent stiffness with interface-local strain. Two-dimensional axisymmetric finite element models were subjected to a spatially uniform nominal pressure of 1.00 MPa. Nine D / R ratios (0.33–3.25) and eleven homogeneous donor/recipient (DC/RC) Young’s modulus combinations (2.50-7.00 MPa) yielded 99 homogeneous cases; nine functionally graded material (FGM) cases were evaluated. Primary outcomes were 95th percentile (P95) values of the nodewise compressive strain magnitude and tensor maximum shear strain within a fixed 0.25-mm local interface region of interest (ROI). This robust upper-tail measure is less sensitive than a single nodal maximum. In the matched homogeneous control, P95 values were 0.031 and 0.015. The largest homogeneous values were 0.412 and 0.347 at D / R =3.25 and DC/RC=7.0/2.5 MPa. Same-side concentration factors normalized local P95 to median strain in the same model’s 0.75-1.00 mm far-field band. Pooled factors were 3.71 ± 2.04 for compression and 6.03 ± 3.79 for maximum shear in homogeneous cases ( n = 198 model-sides), and 3.51 ± 2.17 and 5.69 ± 4.03 in FGM cases ( n = 18). FGM values were lower than both extreme homogeneous mismatch references at every D / R ratio. Across formulations, thickness disparity remained associated with interface-local upper-tail strain. These results support evaluating donor-recipient cartilage thickness and material compatibility alongside surface congruity and osseous integration in future experimental and patient-specific modeling studies.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →