A monolithic patient-specific 3D–0D model for In silico investigation of hemodynamics in patients with left ventricular assist devices

Mia Bonini, Marc Hirschvogel, Michael Ferguson, Francis Pagani, Paul C. Tang, David Nordsletten

Biomechanics and Modeling in Mechanobiology · 2026-06 · 25 (3)

DOI: 10.1007/s10237-026-02063-9 ↗
AbstractBibliografische Angaben

Abstract

Abstract We present a fully coupled, patient-specific 3D–0D computational framework for hearts supported with left ventricular assist devices (LVAD) that enables controlled in silico experimentation. The approach monolithically integrates three-dimensional CFD of the left ventricle (LV), left atrium (LA), aortic root, and LVAD cannulae with a closed-loop 0D lumped parameter network of the full circulation. Mitral and aortic valve dynamics are governed by transvalvular pressure and flow with patient-specific regurgitant orifice areas, and the LVAD is represented via a pressure–flow (H–Q) relation. This manuscript provides the complete mathematical formulation, coupling strategy, and parameterization required to build a reproducible pipeline from dynamic CT, 2D transthoracic echocardiography, and right heart catheterization. This methodology is demonstrated in a patient under long-term support of LVAD and concomitant mitral and aortic regurgitation. The personalized, fully coupled 3D–0D models reproduced available clinical targets with a mean error of 8.6%, enabling controlled in silico interrogation of valve repair strategies. In the patient-specific state, simulated mitral and aortic regurgitant volumes were 6.6 and 6.5 mL per cycle, yielding a forward cardiac output of 3.16 L/min despite an LVAD flow of 3.7 L/min. In silico isolated mitral valve (MV) repair, isolated aortic valve (AV) repair, and combined MV+AV repair increased forward output to 3.41, 3.33, and 3.55 L/min, respectively; however, aortic valve opening and increased aortic pressure pulsatility (up to 38.9 vs. 13.5 mmHg) were observed only when MV repair was involved. These left-sided improvements propagated through the cardiopulmonary circulation, reducing pulmonary pressures and right ventricular loading, with the largest benefit observed following combined repair. We show that the modeling platform presented provides a powerful means to study mechanical circulatory support, enabling patient-specific evaluation of surgical interventions in patients with LVAD and delivering quantitative insight into clinically important metrics—such as aortic pulsatility, RV afterload, and chamber-level flow patterns.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →