EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Gestational age-specific reference ranges and Z-score equations for fetal aortic and pulmonary valve annulus diameters at 18–24 weeks of gestation

Fatma Beyhekim, Hasan Beyhekim, Zekiye Soykan Sert, Gökçen Örgül, Merve Nur Taşpınar, Aybike Tazegül Pekin

Archives of Gynecology and Obstetrics · 2026-11-04

DOI: 10.1007/s00404-026-08596-9 ↗
AbstractBibliografische Angaben

Abstract

Abstract Purpose To establish gestational age-specific reference ranges and internally validated Z -score equations for fetal aortic (AV) and pulmonary valve (PV) annulus diameters between 18 + 0 and 24 + 6 weeks of gestation in a routine screening population, and to evaluate the PV/AV ratio as a parameter of proportionate semilunar valve growth. Methods In this single-center retrospective cross-sectional study, 2,662 singleton fetuses were examined. AV and PV annulus diameters were measured in systole at maximal opening by a single operator. Linear regression models were fitted using gestational age in days, with gestational age-dependent standard deviations to account for increasing residual variance. Held-out internal validation was performed by tenfold cross-validation, with the complete modeling procedure refitted within each training fold and applied to untouched held-out folds; bootstrap resampling was used to assess coefficient stability. Results The final regression equations were AV = 2.9273 + 0.0342 × (GA − 150) ( R 2 = 0.370) and PV = 3.6650 + 0.0420 × (GA − 150) ( R 2 = 0.395). In held-out validation, the pooled mean Z -score was + 0.023 (SD 1.048) for AV and + 0.016 (SD 1.046) for PV, with 93.86 and 93.49% of observations within ± 1.96 Z -score units (nominal 0, 1 and 95%). The mean PV/AV ratio was 1.262 (SD 0.146) and remained stable across gestation ( R 2 < 0.001). Conclusions These internally validated reference ranges and Z -score equations may support standardized second-trimester assessment of fetal semilunar valve dimensions. The stable PV/AV ratio may provide an additional parameter for assessing proportionate semilunar valve growth during routine anomaly scanning.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →