Evaluation of a non‐radioactive rapid test for determination of serum progesterone in South American camelids
Veterinary Record · 03.10.2026 · 199 (7)
DOI: 10.1002/vetr.6027 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Veterinary Record, online erschienen am 04.12.2025. Verfasst von Lina Längerer und 5 weiteren Autor:innen. Beteiligte Einrichtung: Veterinary Clinic for Reproductive Medicine and Neonatology, Justus Liebig University Giessen, Giessen, Germany. Hauptthemen laut MEDLINE: Progesterone, Camelids, New World, Pregnancy Tests. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Determination of the serum progesterone (P4) concentration is of high importance in reproductive medicine and may be applied for diagnosing pregnancy in South American camelids. P4 measurements in alpacas and llamas are usually performed using immunoassays, which are time consuming and require appropriate expertise of laboratory staff. In this study, the suitability of a commercial automated enzyme‐linked immunofluorescence assay using a mini‐VIDAS device (bioMérieux) for P4 determination in South American camelids was investigated.
Methods
Serum was prepared from the whole blood samples from 116 alpacas and 73 llamas; each sample was divided into two aliquots and stored at –20°C. Comparative P4 measurements were performed using the mini‐VIDAS method and an in‐house radioimmunoassay as the reference standard.
Results
The results showed a strong positive correlation between the results of the two methods (Spearman's rank correlation alpaca: rs = 0.9168 [ p < 0.05]; llama: rs = 0.9040 [ p < 0.05]).
Limitations
Although the measuring methods are highly correlated, deviations from the reference method occurred in the high measurement range of mini‐VIDAS.
Conclusions
This study confirmed that the mini‐VIDAS is suitable for determining serum P4 concentration in domestic South American camelids and provides reliable results in less than 1 hour.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Veterinary Clinic for Reproductive Medicine and Neonatology, Justus Liebig University Giessen, Giessen, Germany.
- Unit of Biomathematics and Data Processing, Faculty of Veterinary Medicine, Justus Liebig University Giessen, Giessen, Germany.
ORCID-Profile: Lina Längerer
Zitieren
APA
Längerer, L., Schuler, G., Pohlscheid, P., Wagner, H., Büttner, K., & Wehrend, A. (2026). Evaluation of a non‐radioactive rapid test for determination of serum progesterone in South American camelids. Veterinary Record, 199(7). https://doi.org/10.1002/vetr.6027
Vancouver
Längerer L, Schuler G, Pohlscheid P, Wagner H, Büttner K, Wehrend A. Evaluation of a non‐radioactive rapid test for determination of serum progesterone in South American camelids. Veterinary Record. 2026;199(7). doi:10.1002/vetr.6027
BibTeX
@article{Lngerer2026,
author = {Längerer, Lina and Schuler, Gerhard and Pohlscheid, Philipp and Wagner, Henrik and Büttner, Kathrin and Wehrend, Axel},
title = {Evaluation of a non‐radioactive rapid test for determination of serum progesterone in South American camelids},
journal = {Veterinary Record},
year = {2026},
volume = {199},
number = {7},
doi = {10.1002/vetr.6027}
}
EUVIMED