EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Improved detection in untargeted lipidomics through silver‐doped infrared matrix‐assisted laser desorption electrospray ionization

Seth M Eisenberg iD, David C Muddiman

Rapid Communications in Mass Spectrometry · 2024

DOI: 10.1002/rcm.9832 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, 2024. Verfasst von Seth M Eisenberg und 1 weiteren Autor:innen. Beteiligte Einrichtung: FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA. Hauptthemen laut MEDLINE: Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization, Lipids, Liver, Spectrometry, Mass, Electrospray Ionization. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIGMS NIH HHS, NIH HHS, National Institute of General Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rationale

Silver doping of electrospray is known to increase the abundance of olefinic compounds detected by mass spectrometry. While demonstrated in targeted experiments, this has yet to be investigated in an untargeted study. Utilizing infrared matrix‐assisted laser desorption electrospray ionization mass spectrometry imaging (IR‐MALDESI‐MSI), an untargeted lipidomics experiment on mouse liver was performed to evaluate the advantages of silver‐doped electrospray.

Methods

10 ppm silver nitrate was doped into the IR‐MALDESI solvent consisting of 60% acetonitrile and 0.2% formic acid. Using an Orbitrap mass spectrometer in positive ionization mode, MSI was performed, analyzing from m / z 150 to m / z 2000 to capture all lipids with potential silver adducts. The lipids detected in the control and silver‐doped electrosprays were compared by annotating using the LIPID MAPS Structural Database and eliminating false positives using the metabolite annotation confidence score.

Results

Silver‐doped electrospray allowed for the detection of such ions of lipid molecules as [M + H] + or [M + NH 4 ] + and as [M + Ag] + . Among the ions seen as [M + H] + or [M + NH 4 ] + , the signal was comparable between the control and silver‐doped electrosprays. The silver‐doped electrospray led to a 10% increase in the number of detected lipids, all of which contained a bay region increasing the interaction between silver and alkenes. Silver preferentially interacted with lipids that did not contain hard bases such as phosphates.

Conclusions

Silver‐doped electrospray enabled detection of 10% more olefinic lipids, all containing bay regions in their putative structures. This technique is valuable for detecting previously unobserved lipids that have the potential to form bay regions, namely fatty acyls, glycerolipids, prenol lipids, and polyketides.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationLipidsLiverSpectrometry, Mass, Electrospray IonizationLipidomicsSilverAnimalsMice

Substanzen

LipidsSilver

Autor:innen und Institutionen

  • FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA.

ORCID-Profile: Seth M Eisenberg

Förderung

  • NIGMS NIH HHS
  • NIH HHS
  • National Institute of General Medical Sciences
  • National Institutes of Health

Zitieren

APA

Eisenberg, S. M., & Muddiman, D. C. (2024). Improved detection in untargeted lipidomics through silver‐doped infrared matrix‐assisted laser desorption electrospray ionization. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.9832

Vancouver

Eisenberg SM, Muddiman DC. Improved detection in untargeted lipidomics through silver‐doped infrared matrix‐assisted laser desorption electrospray ionization. Rapid Communications in Mass Spectrometry. 2024. doi:10.1002/rcm.9832

BibTeX
@article{Eisenberg2024,
  author = {Eisenberg, Seth M and Muddiman, David C},
  title = {Improved detection in untargeted lipidomics through silver‐doped infrared matrix‐assisted laser desorption electrospray ionization},
  journal = {Rapid Communications in Mass Spectrometry},
  year = {2024},
  doi = {10.1002/rcm.9832}
}
Kostenlos starten →