Evaluating the optimal tissue thickness for mass spectrometry imaging using infrared matrix‐assisted laser desorption electrospray ionization
Rapid Communications in Mass Spectrometry · 2023
DOI: 10.1002/rcm.9638 ↗Kurz gefasst
Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, 2023. Verfasst von Alena N Joignant und 3 weiteren Autor:innen. Beteiligte Einrichtung: FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA. Hauptthemen laut MEDLINE: Spectrometry, Mass, Electrospray Ionization, Histological Techniques. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIGMS NIH HHS, NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Rationale
Infrared matrix‐assisted laser desorption electrospray ionization (IR‐MALDESI) utilizes a 2970 nm mid‐IR laser to desorb samples with depth resolutions ( Z ) on the order of micrometers. Conventionally, 5–20 μm thick tissue sections are used to characterize different applications of the IR‐MALDESI source, but an optimal thickness has not been systematically investigated.
Methods
Mouse liver was sectioned to various thicknesses and analyzed using IR‐MALDESI mass spectrometry imaging (MSI). Height profiles of tissue sections of various cryosectioned thicknesses were acquired to affirm tissue thickness. Tissue sections of each thickness were measured using a Keyence microscope. Paraffin wax was cryosectioned, mounted on microscope slides, and measured using a chromatic confocal sensor system to determine the cryostat sectioning accuracy.
Results
Analyzing sectioned tissues at higher thickness (>10 μm) leads to lower ion abundance, a decrease in signal over long analysis times, and more frequent instrument cleaning. Additionally, increasing tissue thickness above the optimum (7 μm) does not result in a significant increase in lipid annotations.
Conclusions
This work defines an optimal sample thickness for IR‐MALDESI‐MSI and demonstrates the utility of optimizing tissue thickness for MSI platforms of comparable Z resolution.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA.
Förderung
- NIGMS NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Joignant, A. N., Knizner, K. T., Xi, Y., & Muddiman, D. C. (2023). Evaluating the optimal tissue thickness for mass spectrometry imaging using infrared matrix‐assisted laser desorption electrospray ionization. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.9638
Vancouver
Joignant AN, Knizner KT, Xi Y, Muddiman DC. Evaluating the optimal tissue thickness for mass spectrometry imaging using infrared matrix‐assisted laser desorption electrospray ionization. Rapid Communications in Mass Spectrometry. 2023. doi:10.1002/rcm.9638
BibTeX
@article{Joignant2023,
author = {Joignant, Alena N and Knizner, Kevan T and Xi, Ying and Muddiman, David C},
title = {Evaluating the optimal tissue thickness for mass spectrometry imaging using infrared matrix‐assisted laser desorption electrospray ionization},
journal = {Rapid Communications in Mass Spectrometry},
year = {2023},
doi = {10.1002/rcm.9638}
}
EUVIMED