Preference matters: New aspects on how foreign bodies should and could be removed from a child's airway
Pediatric Pulmonology · 2023
DOI: 10.1002/ppul.26411 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pediatric Pulmonology, 2023. Verfasst von Nadine Freitag und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of General Pediatrics, Neonatology and Pediatric Cardiology, Medical Faculty, University Hospital Düsseldorf, Düsseldorf, Germany. Hauptthemen laut MEDLINE: Bronchoscopy, Foreign Bodies. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Foreign body aspiration in children is a potentially life‐threatening event that can be diagnosed and treated by airway endoscopy. We aimed to analyze the influence of the examiner's experience and preference on the choice of the technique and the resulting complication rate.
Methods
In this international study, experts in the field documented their preferred and applied technique as well as the outcome of each case of foreign body removal. Personal data of the bronchoscopists and their medical center were collected via an online questionnaire separately from the case specifics.
Results
A total of 399 foreign body removals were performed by 64 examiners. A total of 279 removals were performed using rigid endoscopy, and 120 procedures were performed by flexible. When a difficulty was expected, flexible endoscopy was used significantly more often (χ 2 (1) = 11.06, p < 0.001). Complications occurred significantly less often when the bronchoscopist used their preferred technique (χ 2 (1) = 6.41, p = 0.011), had more than 5 years of experience (χ 2 (1) = 5.13, p = 0.023) or performed more than 100 removals (χ 2 (2) = 11.51, p = 0.003). In medical centers, complication rates significantly decreased if more than 200 bronchoscopies were performed in children, compared to the centers that perform 50–200 bronchoscopies per year (χ 2 (1) = 24.56, p < 0.001).
Conclusion
Preference and experience of a bronchoscopist and his/her medical center with flexible or rigid foreign body removal distinctively affect the outcome of the procedure and cannot be neglected in the discourse on the appropriate technique. This link also emphasizes the importance of a structured training program.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of General Pediatrics, Neonatology and Pediatric Cardiology, Medical Faculty, University Hospital Düsseldorf, Düsseldorf, Germany.
- Ruhr University Bochum, Children's Hospital St. Josef-Hospital, Bochum, Germany.
- Department of Otorhinolaryngology, Medical Faculty, University Hospital Düsseldorf, Düsseldorf, Germany.
- Division of Pediatric Pulmonology, Department of Pediatrics, Mount Sinai Kravis Children's Hospital, Icahn School of Medicine at Mount Sinai, New York, New York, USA.
ORCID-Profile: Nadine Freitag, Alfin Vicencio, Dirk Schramm
Zitieren
APA
Freitag, N., Möllenberg, L., Wiemers, A., Bosse, H. M., Kristin, J., Vicencio, A., & Schramm, D. (2023). Preference matters: New aspects on how foreign bodies should and could be removed from a child's airway. Pediatric Pulmonology. https://doi.org/10.1002/ppul.26411
Vancouver
Freitag N, Möllenberg L, Wiemers A, Bosse HM, Kristin J, Vicencio A, et al. Preference matters: New aspects on how foreign bodies should and could be removed from a child's airway. Pediatric Pulmonology. 2023. doi:10.1002/ppul.26411
BibTeX
@article{Freitag2023,
author = {Freitag, Nadine and Möllenberg, Leon and Wiemers, Anna and Bosse, Hans Martin and Kristin, Julia and Vicencio, Alfin and Schramm, Dirk},
title = {Preference matters: New aspects on how foreign bodies should and could be removed from a child's airway},
journal = {Pediatric Pulmonology},
year = {2023},
doi = {10.1002/ppul.26411}
}
EUVIMED