EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Application of transcranial Doppler in the diagnosis and management of cervical artery dissection: Insights from a multicenter survey within the STOP‐CAD study

Xiaofan Guo, Behnam Sabayan, Benjamin Shifflett, Muhib Khan, Kateryna Antonenko, Mirjam R. Heldner, Michele Romoli, João Pedro Marto, Zafer Keser, Aaron Rothstein, Ossama Khazaal, Marwa Elnazeir, Harjot Hansra, Brett C. Meyer, Dawn M. Meyer, Reza Bavarsad Shahripour

Clinical Neuroimaging · 2024

DOI: 10.1002/neo2.70004 ↗
AbstractBibliografische Angaben

Abstract

Abstract Background Cervical artery dissection (CAD) is a common cause of ischemic stroke in young adults. Local blood clot formation and distal emboli are the key mechanisms for the development of stroke in patients with CAD. Microemboli distal to the dissection point can be detected as high‐intensity transient signals (HITS) using transcranial Doppler (TCD). Despite this unique capability, TCD is used inconsistently in the management of CAD. In this international survey, we aim to explore the frequency and potential barriers to TCD use in CAD. Method This study was an international electronic survey, based on the Antithrombotic Treatment for Stroke Prevention in Cervical Artery Dissection (STOP‐CAD) study, aiming at evaluating the use of TCD in diagnosing and managing CAD patients. A comprehensive questionnaire was developed to gather insights into the current practices, perceptions, and potential barriers to the effective use of TCD in participating centers. The collected data was then analyzed. Results Fifty‐eight medical centers with advanced stroke care capabilities from Europe and United States participated in this study. Half (29 out of 58) of the sites routinely perform TCD on CAD patients, particularly in the presence of carotid or vertebral artery stenosis, complete carotid occlusion, and early neurologic deterioration. The primary reason for participating institutions not performing TCD was because its results would not change their practice. The protocol for TCD monitoring and managing HITS‐positive CAD patients varied among centers but transitioning from antiplatelet to anticoagulant was the most common practice in this patient population. Conclusion Half of the stroke centers in our survey routinely perform TCD monitoring for CAD patients. The detection of HITS in CAD patients is a warning sign for providers, which may prompt a change in secondary stroke prevention management. However, a standard protocol for performing TCD in CAD and treatment recommendations for HITS‐positive CAD are not currently available, which warrants further research.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →