EUVIMEDEUVIMED entdecken
CrossrefInfokarte

A Mixed Single‐Echo and Multiecho MyoFoldstar for Simultaneous Quantification of Myocardial T 1 , T 2 , T 2 *, and Wall Motion

Rui Guo, Guozhao Dong, Bowei Liu, Yu Lian, Yifei Jiang, Xiaomeng Yang, Peng Wu, Yingwei Fan, Ancong Wang, Jingjing Xiao, Haiyan Ding, Xiaoying Tang

NMR in Biomedicine · 2026-07 · 39 (7)

DOI: 10.1002/nbm.70320 ↗
AbstractBibliografische Angaben

Abstract

ABSTRACT This study aimed to propose a mixed single‐echo and multiecho MyoFoldstar sequence enabling simultaneous myocardial multiparametric mapping and wall‐motion quantification. MyoFoldstar is designed as a 2D, single breath‐holding sequence that sequentially performs joint T 1 / T 2 mapping, T 2 * mapping, and cine imaging within 17 heartbeats, using a golden‐angle radial gradient‐echo (GRE) readout and ECG synchronization. The joint T 1 / T 2 mapping collects seven single‐shot, single‐echo images on the first seven heartbeats with inversion and T 2 preparation ( T 2 prep). The subsequent T 2 * mapping acquires multishot, multiecho data over six heartbeats, followed by segmented cine with a single‐echo readout over four heartbeats. In vivo feasibility was demonstrated in 12 healthy volunteers at 3 T and compared with conventional single‐task sequences (MOLLI and SASHA for T 1 , T 2 prep bSSFP for T 2 , and BB‐meGRE for T 2 *). Accuracy was validated in phantom studies. Both in vivo and phantom studies demonstrated the feasibility of MyoFoldstar for simultaneously acquiring cardiac T 1 , T 2 , T 2 *, and cine imaging. MyoFoldstar‐derived myocardial T 1 (1521 ± 102 ms), T 2 (43.2 ± 3.0 ms), and T 2 * (19.2 ± 2.4 ms) showed good agreement with values from conventional single‐task sequences ( T 1 : 1248 ± 35 ms by MOLLI and 1580 ± 38 ms by SASHA; T 2 : 43.5 ± 2.2 ms by T 2 prep bSSFP; T 2 *: 23.4 ± 2.6 ms by BB‐meGRE). Compared with conventional cine, MyoFoldstar images exhibited reduced myocardium–blood contrast, yet left ventricular function quantifications were mainly preserved ( r > 0.9). Phantom results indicated that MyoFoldstar achieves good accuracy relative to reference standards. MyoFoldstar enables rapid myocardial T 1 , T 2 , T 2 *, and cine imaging within a single breath‐hold scan, delivering a time‐saving and comprehensive assessment of cardiovascular magnetization resonance.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →