EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Optimizing Oscillating Diffusion Gradients to Reduce Mechanical Vibration and Acoustic Noise on Ultra‐High Gradient Scanners

Xingzhou Chen, Liyi Kang, Haotian Li, Chengbo Wang, Zhuming Shuai, Jiayu Zhu, Jianmin Yuan, Dan Wu

Magnetic Resonance in Medicine · 2027-01 · 97 (1) · 425-440

DOI: 10.1002/mrm.70580 ↗
AbstractBibliografische Angaben

Abstract

ABSTRACT Purpose The deployment of oscillating gradient spin echo (OGSE) diffusion encoding sequences on ultra‐high gradient scanners enables advanced microstructure imaging but induces intense acoustic noise and mechanical vibrations, causing subject discomfort and compromising imaging stability and quantitative accuracy. This study implements Acoustic noise and Vibration Optimized dIffusion gradient Design (AVOID) to mitigate these side effects, facilitating the high‐performance OGSE applications in demanding hardware environments. Methods System transfer functions were measured on a 3.0T ultra‐high gradient NeuroFrontier MRI system to characterize hardware responses. The optimization algorithm reshaped OGSE waveforms by redistributing spectral energy away from resonant frequencies while maintaining multiple constraints including hardware limits and desired diffusion encoding spectrum. The optimization was validated by comparing non‐optimized and optimized waveforms through physical measurements, phantom scans, and in vivo human brain scans. Results Reductions of up to 10 dBA in predicted sound pressure level and 3.4 dB in vibration power spectral intensity were achieved. In phantom experiments, vibration‐induced artifacts were significantly mitigated, resulting in superior repeatability and lower coefficients of variation in ADC maps, approaching the minimum‐vibration reference by pulsed gradient sequences. In vivo validation demonstrated enhanced acquisition stability and consistent frequency‐dependent ADC trends from 0 to 120 Hz. Conclusion The AVOID framework effectively suppressed intense acoustic noise and mechanical vibration induced by strong oscillating gradients on ultra‐high gradient scanners, ensuring a stable and comfortable environment for advanced microstructural imaging.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →