EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Uncertainty Quantification for Cardiac Diffusion Tensor Imaging Without Additional Datasets

Sam Coveney iD, Irvin Teh iD, May Lwin iD, Mehak Asad iD, Isaac Watson iD, Maryam Afzali iD, Erica Dall'Armellina iD, Jürgen E Schneider iD

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70414 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Sam Coveney und 7 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Imaging Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK. Hauptthemen laut MEDLINE: Diffusion Tensor Imaging, Heart, Image Processing, Computer-Assisted, Cardiomyopathy, Hypertrophic. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: British Heart Foundation, Wellcome Trust.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Cardiac diffusion tensor imaging (cDTI) is subject to physiological noise, thermal noise, and signal corruption, which cause errors in diffusion measures. While a larger dataset can be decimated to investigate the general precision of measures from fitting smaller datasets, uncertainty quantification (UQ) methods for fitting entire particular datasets are required for UQ to be output from cDTI post‐processing pipelines. Theory and Methods To account for non‐idealized errors in cDTI, repetition bootstrap methods with whole‐image resampling are required to approximate the sampling distribution of measures. We demonstrate UQ of voxel‐wise diffusion measures and myocardial summary statistics over multiple voxels, as well as uncertainty‐weighted summary statistics and their uncertainties. Methods are demonstrated on datasets of healthy volunteers and hypertrophic cardiomyopathy patients.

Results

Group differences are larger (and p values smaller) for MD, FA and when myocardial averages of diffusion measures are weighted by uncertainty. This is particularly true for (difference of group medians: for unweighted average, for uncertainty weighted average). The uncertainty of averages over myocardial voxels is useful to understand outlier cases where it is difficult to determine if the result is trustworthy from diffusion measures alone. Uncertainty maps are also useful for highlighting regions of less trustworthy diffusion measures.

Conclusion

Uncertainty quantification in cardiac diffusion tensor imaging can be performed with respect to the sampling distribution of the available cDTI dataset, provided the dataset design is suitable for repetition bootstrapping.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diffusion Tensor ImagingHeartImage Processing, Computer-AssistedCardiomyopathy, HypertrophicImage Interpretation, Computer-AssistedHumansAlgorithmsMaleReproducibility of ResultsUncertaintyAdultFemaleMyocardium

Stichwörter der Autor:innen

bootstrapcardiac diffusion tensor imagingmagnetic resonance imagingsampling distributionuncertainty quantification

Autor:innen und Institutionen

  • Biomedical Imaging Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK.
  • Division of Cardiovascular Sciences, College of Life Sciences, University of Leicester, Leicester, UK.

ORCID-Profile: Sam Coveney, Irvin Teh, May Lwin, Mehak Asad, Isaac Watson, Maryam Afzali, Erica Dall'Armellina, Jürgen E Schneider

Förderung

  • British Heart Foundation
  • Wellcome Trust

Zitieren

APA

Coveney, S., Teh, I., Lwin, M., Asad, M., Watson, I., Afzali, M., Dall'Armellina, E., & Schneider, J. E. (2026). Uncertainty Quantification for Cardiac Diffusion Tensor Imaging Without Additional Datasets. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70414

Vancouver

Coveney S, Teh I, Lwin M, Asad M, Watson I, Afzali M, et al. Uncertainty Quantification for Cardiac Diffusion Tensor Imaging Without Additional Datasets. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70414

BibTeX
@article{Coveney2026,
  author = {Coveney, Sam and Teh, Irvin and Lwin, May and Asad, Mehak and Watson, Isaac and Afzali, Maryam and Dall'Armellina, Erica and Schneider, Jürgen E},
  title = {Uncertainty Quantification for Cardiac Diffusion Tensor Imaging Without Additional Datasets},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70414}
}
Kostenlos starten →