Rapid Tissue‐ CSF Water Exchange in the Human Brain Revealed by Magnetization Transfer Indirect Spin Labeling
Magnetic Resonance in Medicine · 2026-06 · 95 (6) · 3270-3283
DOI: 10.1002/mrm.70298 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 09.02.2026. Verfasst von Yihan Wu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain Neoplasms, Brain, Body Water. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, NHLBI NIH HHS, NIA NIH HHS.
Abstract (Originalsprache)
Purpose
To apply the Magnetization Transfer Indirect Spin Labeling (MISL) MRI technique for quantifying tissue‐CSF water exchange in the human brain, and to investigate its utility in (1) evaluating tissue‐CSF water exchange within perivascular spaces (PVS), and (2) characterizing altered water exchange dynamics in pathologic conditions.
Methods
MISL was implemented on a 3 T MRI using off‐resonance magnetization transfer to label parenchymal water. The resulting exchange with CSF was captured via long‐TE 3D‐TSE readout to suppress parenchymal signals. CSF‐region‐specific quantification was achieved by atlas‐based segmentation. Studies were conducted in healthy subjects across age groups and in patient with metastatic brain tumor.
Results
MISL revealed widespread and regionally heterogeneous tissue‐CSF exchange, with the strongest signals observed in the PVS and areas adjacent to the choroid plexus. MISL signals were typically 2%–3% in the ventricles and subarachnoid space, and reached 3% in the cerebellar regions, suggesting tissue‐to‐CSF flow (TCF) in the range of 100–300 mL/100 mL/min. The high MISL signals observed in the PVS (∼8.4%) indicated active tissue‐CSF water exchange, providing functional information of the PVS that conventional T2w imaging cannot capture. Significant age‐dependent declines in TCF were observed across most brain regions, except for the third and fourth ventricles. In the tumor patient, MISL revealed elevated water exchange, even where no overt FLAIR hyperintensity was present.
Conclusion
MISL enables robust, non‐invasive mapping of tissue‐CSF exchange with high sensitivity and spatial resolution. MISL provides a unique window into tissue‐CSF exchange within PVS, which may reflect glymphatic function.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland, USA.
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA.
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
- Department of Radiology, University of Washington, Seattle, Washington, USA.
- Department of Radiation Oncology and Radiation Molecular Sciences, Johns Hopkins University, Baltimore, Maryland, USA.
ORCID-Profile: Kexin Wang, Qin Qin, Feng Xu, Jiadi Xu
Förderung
- NIBIB NIH HHS
- NHLBI NIH HHS
- NIA NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Wu, Y., Wang, K., Ju, L., Li, A., Qin, Q., Xu, F., Lin, D. D. M., Kleinberg, L., & Xu, J. (2026). Rapid Tissue‐ CSF Water Exchange in the Human Brain Revealed by Magnetization Transfer Indirect Spin Labeling. Magnetic Resonance in Medicine, 95(6), 3270-3283. https://doi.org/10.1002/mrm.70298
Vancouver
Wu Y, Wang K, Ju L, Li A, Qin Q, Xu F, et al. Rapid Tissue‐ CSF Water Exchange in the Human Brain Revealed by Magnetization Transfer Indirect Spin Labeling. Magnetic Resonance in Medicine. 2026;95(6):3270-3283. doi:10.1002/mrm.70298
BibTeX
@article{Wu2026,
author = {Wu, Yihan and Wang, Kexin and Ju, Licheng and Li, Anna and Qin, Qin and Xu, Feng and Lin, Doris D M and Kleinberg, Lawrence and Xu, Jiadi},
title = {Rapid Tissue‐ CSF Water Exchange in the Human Brain Revealed by Magnetization Transfer Indirect Spin Labeling},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {95},
number = {6},
pages = {3270--3283},
doi = {10.1002/mrm.70298}
}
EUVIMED