EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

On‐Scanner Correction of Gradient Nonlinearity Bias for Accurate Assessment of Diffusion Heterogeneity Across Bone Sites in Myelofibrosis Patients

Dariya Malyarenko iD, Brian D Ross, Johannes M Peeters, Ajit Devaraj, Ramin Jafari, Humera Tariq iD, Kristen M Pettit, Moshe Talpaz, Gary D Luker, Thomas L Chenevert

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70273 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Dariya Malyarenko und 9 weiteren Autor:innen. Beteiligte Einrichtung: Radiology, University of Michigan, Ann Arbor, Michigan, USA. Hauptthemen laut MEDLINE: Primary Myelofibrosis, Bone Marrow, Diffusion Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To improve accuracy of apparent diffusion coefficient (ADC) measurement across different bone‐marrow (BM) sites for myelofibrosis (MF) patients.

Methods

Vendor‐provided ADC gradient nonlinearity correction (GNC) was implemented for 41 MF study subjects on a 3T clinical scanner. The degree of bias correction was assessed on b‐maps across the BM regions‐of‐interest defined for femoral trochanter, posterior ilium and spine vertebrae of all subjects. Bias variability from subject repositioning was evaluated for five subjects with longitudinal scans using Bland–Altman analysis. BM ADC with and without GNC were compared in 22 subjects with MF grade > 0 (iliac fat fraction < 40%). The GNC effect on ADC heterogeneity trends across bone sites was assessed using paired t‐test and correlation to MF‐grade.

Results

The observed bias was substantial across BM sites ranging from −10% for edge vertebrae to +8.4% for trochanter across all subjects with a 13.7% intra‐subject median range. The effect of irreproducible positioning in longitudinal scans was ±4.2% bias (95% limits‐of‐agreement) with range of ±8.5% (highest for L1 and L5). By removing bias, GNC improved ADC accuracy and longitudinal reproducibility and emphasized biological heterogeneity for femoral trochanter versus ilium and edge vertebrae (T11‐L1, L5, and S1). GNC revealed significant ADC differences between trochanters and edge vertebrae ( p = 0.007), while edge vertebrae and ilium ADC became more uniform ( p = 0.07), with heterogeneity and values correlated to MF‐grade.

Conclusion

On‐scanner correction of gradient nonlinearity bias in bone marrow ADC reduces technical nonuniformity and variability and allows accurate and reproducible characterization of heterogeneous disease for myelofibrosis patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Primary MyelofibrosisBone MarrowDiffusion Magnetic Resonance ImagingImage Processing, Computer-AssistedBone and BonesHumansFemaleMaleAgedMiddle AgedReproducibility of ResultsIliumAlgorithmsAdultImage Interpretation, Computer-AssistedSpine

Stichwörter der Autor:innen

ADC nonuniformitybone marrowgradient nonlinearitymyelofibrosisnonuniform diffusion weighting

Autor:innen und Institutionen

  • Radiology, University of Michigan, Ann Arbor, Michigan, USA.
  • MR Clinical Science, Philips Healthcare, Best, the Netherlands.
  • MR Clinical Science Philips, Cambridge, Massachusetts, USA.
  • Internal Medicine, University of Michigan, Ann Arbor, Michigan, USA.

ORCID-Profile: Dariya Malyarenko, Humera Tariq

Förderung

  • NCI NIH HHS
  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Malyarenko, D., Ross, B. D., Peeters, J. M., Devaraj, A., Jafari, R., Tariq, H., Pettit, K. M., Talpaz, M., Luker, G. D., & Chenevert, T. L. (2026). On‐Scanner Correction of Gradient Nonlinearity Bias for Accurate Assessment of Diffusion Heterogeneity Across Bone Sites in Myelofibrosis Patients. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70273

Vancouver

Malyarenko D, Ross BD, Peeters JM, Devaraj A, Jafari R, Tariq H, et al. On‐Scanner Correction of Gradient Nonlinearity Bias for Accurate Assessment of Diffusion Heterogeneity Across Bone Sites in Myelofibrosis Patients. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70273

BibTeX
@article{Malyarenko2026,
  author = {Malyarenko, Dariya and Ross, Brian D and Peeters, Johannes M and Devaraj, Ajit and Jafari, Ramin and Tariq, Humera and Pettit, Kristen M and Talpaz, Moshe and Luker, Gary D and Chenevert, Thomas L},
  title = {On‐Scanner Correction of Gradient Nonlinearity Bias for Accurate Assessment of Diffusion Heterogeneity Across Bone Sites in Myelofibrosis Patients},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70273}
}
Kostenlos starten →