EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access

Deep Learning‐Based Denoising for High‐Resolution Carotid Vessel Wall MRI Using Standard Neurovascular Coils

Lisha Zeng iD, Yin-Chen Hsu iD, Lixia Wang iD, Meng Lu, Mary Keushkerian iD, Kim-Lien Nguyen iD, Kevin J Johnson, Maria I Altbach, H Douglas Morris, J Kevin DeMarco, Vibhas Deshpande, Dimitrios Mitsouras und 9 weitere

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.70226 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Lisha Zeng und 20 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA. Hauptthemen laut MEDLINE: Deep Learning, Carotid Arteries, Magnetic Resonance Angiography, Image Processing, Computer-Assisted. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, VA, CSRD VA.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop a deep learning ( DL ) denoising method to enhance high‐resolution carotid vessel wall MRI quality acquired using a standard head‐and‐neck clinical coil.

Methods

Fifty‐five scans were performed as part of an ongoing multicenter study. Routine carotid VWI protocol including 2D T1 ‐ and T2 ‐weighted TSE , 3D TOF ‐ MRA , and MPRAGE was performed using simultaneous acquisition from a standard 20‐channel head‐and‐neck coil and a high‐sensitivity Neck‐Shape‐Specific ( NSS ) surface coil. Paired retrospective reconstructions with and without NSS coil elements served as the reference and input, respectively. A supervised DL model employing a residual UNet architecture was optimized and trained to map low‐ SNR inputs to high‐ SNR references, benchmarked against conventional denoising algorithms using quantitative and qualitative metrics.

Results

The DL denoiser substantially reduced noise while preserving vessel‐wall structures across contrast‐weighted sequences. It achieved PSNR > 31 dB and structural similarity index ( SSIM ) > 0.93 versus reference slices. In segmented vessel‐wall and lumen regions of interest ( ROIs ), the DL approach achieved significantly higher SNR and CNR values than input images ( p < 0.05), closely approaching the reference. Furthermore, inner‐wall edge sharpness was maintained (Average ERD 7.50–8.51 mm with DL vs. 7.15–8.28 mm with references), supporting confident downstream plaques assessment. Radiologists' Likert ratings corroborated these image‐quality improvements.

Conclusion

A DL ‐based method was developed to improve high‐resolution, multi‐contrast carotid vessel wall MRI acquired using low‐ SNR standard head‐and‐neck coils. The resulting image quality was comparable to that obtained with specialized neck surface coils, potentially enabling broader access to advanced carotid imaging without the need for additional hardware.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningCarotid ArteriesMagnetic Resonance AngiographyImage Processing, Computer-AssistedMagnetic Resonance ImagingHumansSignal-To-Noise RatioAlgorithmsFemaleMaleRetrospective StudiesMiddle AgedAdultAgedImaging, Three-Dimensional

Stichwörter der Autor:innen

carotid surface coildeep learningdenoisingmagnetic resonance imaging (MRI)vessel wall imaging (VWI)

Autor:innen und Institutionen

  • Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.
  • Department of Bioengineering, UCLA, Los Angeles, California, USA.
  • Department of Cardiology, Radiology, and Bioengineering, UCLA, Los Angeles, California, USA.
  • VA Greater Los Angeles Healthcare System, Los Angeles, California, USA.
  • Department of Medical Imaging, University of Arizona, Tucson, Arizona, USA.
  • Department of Biomedical Engineering, University of Arizona, Tucson, Arizona, USA.

ORCID-Profile: Lisha Zeng, Yin-Chen Hsu, Lixia Wang, Mary Keushkerian, Kim-Lien Nguyen, John A Roberts, Debiao Li, Yibin Xie

Förderung

  • NHLBI NIH HHS
  • VA
  • CSRD VA
  • National Heart, Lung, and Blood Institute
  • U.S. Department of Veterans Affairs

Zitieren

APA

Zeng, L., Hsu, Y. C., Wang, L., Lu, M., Keushkerian, M., Nguyen, K. L., Johnson, K. J., Altbach, M. I., Morris, H. D., DeMarco, J. K., Deshpande, V., Mitsouras, D., Saloner, D., McNally, J. S., Kim, S. E., Roberts, J. A., Hadley, J. R., Parker, D. L., Treiman, G. S., …, & Xie, Y. (2025). Deep Learning‐Based Denoising for High‐Resolution Carotid Vessel Wall MRI Using Standard Neurovascular Coils. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70226

Vancouver

Zeng L, Hsu YC, Wang L, Lu M, Keushkerian M, Nguyen KL, et al. Deep Learning‐Based Denoising for High‐Resolution Carotid Vessel Wall MRI Using Standard Neurovascular Coils. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.70226

BibTeX
@article{Zeng2025,
  author = {Zeng, Lisha and Hsu, Yin-Chen and Wang, Lixia and Lu, Meng and Keushkerian, Mary and Nguyen, Kim-Lien and Johnson, Kevin J and Altbach, Maria I and Morris, H Douglas and DeMarco, J Kevin and Deshpande, Vibhas and Mitsouras, Dimitrios and Saloner, David and McNally, J Scott and Kim, Seong-Eun and Roberts, John A and Hadley, J Rock and Parker, Dennis L and Treiman, Gerald S and Li, Debiao and Xie, Yibin},
  title = {Deep Learning‐Based Denoising for High‐Resolution Carotid Vessel Wall MRI Using Standard Neurovascular Coils},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.70226}
}
Kostenlos starten →