Free‐breathing 3D pulmonary ventilation mapping at 0. 55 T using stack‐of‐spiral out‐in bSSFP
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70069 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Ziwei Zhao und 7 weiteren Autor:innen. Beteiligte Einrichtung: Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, Californ…. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Lung, Magnetic Resonance Imaging, Pulmonary Ventilation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Science Foundation, National Science Foundation of Sri Lanka.
Abstract (Originalsprache)
Purpose
To develop a free‐breathing pulmonary imaging technique that provides three‐dimensional ( 3D) structural images and regional ventilation maps, and to evaluate its repeatability and accuracy compared with two‐dimensional phase‐resolved functional lung ( PREFUL ) and global tidal volume.
Methods
A free‐breathing 3D stack‐of‐spiral out‐in ( SOS out‐in) balanced steady‐state free precession (bSSFP) sequence with self‐navigators was designed to achieve 2‐mm isotropic resolution in 5 min. Respiratory‐resolved images were reconstructed using spatial L1 wavelet and temporal finite‐difference constraints. The 3D ventilation maps were generated based on Jacobian determinant of the estimated nonrigid deformations. Six healthy volunteers were scanned in supine and prone positions. Ventilation maps were compared with two‐dimensional PREFUL from two matched slices. Test–retest repeatability was assessed using Bland–Altman analysis. Correlations among the proposed method, PREFUL, and global tidal volume were evaluated.
Results
In healthy volunteers, the SOS out‐in lung images provided sufficient vessel‐parenchyma contrast and boundary sharpness to support accurate ventilation estimation. Regional ventilation measurements from 3D SOS out‐in demonstrated good repeatability (relative differences < 10%). Ventilation maps from 3D SOS out‐in strongly correlated with PREFUL on a slice‐matched basis as well as with global tidal volume ( R 2 > 0.7, p < 0.001).
Conclusion
The proposed method provides high‐quality respiratory‐resolved structural images and 3D ventilation mapping in a single 5‐min scan at 0. 55 T . Ventilation measurements are sensitive, consistent, and in good agreement with PREFUL and spirometry.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA.
- Vista AI, Inc., Palo Alto, California, USA.
- Alfred E. Mann Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA.
- Department of Radiology, Children's Hospital Los Angeles, Los Angeles, California, USA.
- Siemens Medical Solutions USA, Inc, Los Angeles, California, USA.
ORCID-Profile: Ziwei Zhao, Nam G Lee, Bilal Tasdelen, Ye Tian, Bochao Li, Sophia X Cui, Krishna S Nayak
Förderung
- National Science Foundation
- National Science Foundation of Sri Lanka
Zitieren
APA
Zhao, Z., Lee, N. G., Tasdelen, B., Miao, X., Tian, Y., Li, B., Cui, S. X., & Nayak, K. S. (2026). Free‐breathing 3D pulmonary ventilation mapping at 0. 55 T using stack‐of‐spiral out‐in bSSFP. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70069
Vancouver
Zhao Z, Lee NG, Tasdelen B, Miao X, Tian Y, Li B, et al. Free‐breathing 3D pulmonary ventilation mapping at 0. 55 T using stack‐of‐spiral out‐in bSSFP. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70069
BibTeX
@article{Zhao2026,
author = {Zhao, Ziwei and Lee, Nam G and Tasdelen, Bilal and Miao, Xin and Tian, Ye and Li, Bochao and Cui, Sophia X and Nayak, Krishna S},
title = {Free‐breathing 3D pulmonary ventilation mapping at 0. 55 T using stack‐of‐spiral out‐in bSSFP},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70069}
}
EUVIMED