Fast, motion‐robust MR elastography with distributed, generalized encoding
Magnetic Resonance in Medicine · 2025-11 · 94 (5) · 2113-2128
DOI: 10.1002/mrm.30631 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 10.07.2025. Verfasst von Mary K Kramer und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, University of Delaware, Newark, Delaware, USA. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Brain, Magnetic Resonance Imaging, Image Interpretation, Computer-Assisted. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NIH HHS, NIA NIH HHS.
Abstract (Originalsprache)
Purpose
MR elastography (MRE) data are susceptible to poor quality often caused by long scan times and subject motion, due in part to the specific data sampling requirements for determining motion fields to estimate mechanical properties. By reformulating how motion is encoded and estimated, a more efficient and flexible MRE method that allows for accelerated acquisition and motion robustness is established. Theory and Methods A novel motion‐encoding technique was implemented that uses fully distributed sampling directions in an optimized encoding matrix to collect data efficiently. These data are used in an optimization algorithm to estimate harmonic displacement fields. Simulations and in vivo brain MRE data demonstrate the performance of distributed encoding compared with traditional encoding. Estimation of motion from partial data sets after retrospective volume rejection demonstrates new capabilities for robustness to subject motion.
Results
The proposed method achieved significant acceleration over standard methods, allowing for whole‐brain 3D MRE in under 1 min, while maintaining an average 2% difference from traditionally sampled images. If scan time is not prospectively shortened, retrospective removal of images from the data set, such as those corrupted by motion, maintains less than 10% voxel‐wise error after removing up to half of a complete data set.
Conclusion
Through prospective reduction in sampling, reducing acquisition time, and retrospective volume rejection, this distributed encoding technique adds significant capability and flexibility to MRE acquisitions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware, USA.
- Department of Neurology, Massachusetts General Hospital, Boston, Massachusetts, USA.
ORCID-Profile: Mary K Kramer, Curtis L Johnson
Förderung
- NIBIB NIH HHS
- NIH HHS
- NIA NIH HHS
- NINDS NIH HHS
- National Institutes of Health
Zitieren
APA
Kramer, M. K., Cerjanic, A. M., & Johnson, C. L. (2025). Fast, motion‐robust MR elastography with distributed, generalized encoding. Magnetic Resonance in Medicine, 94(5), 2113-2128. https://doi.org/10.1002/mrm.30631
Vancouver
Kramer MK, Cerjanic AM, Johnson CL. Fast, motion‐robust MR elastography with distributed, generalized encoding. Magnetic Resonance in Medicine. 2025;94(5):2113-2128. doi:10.1002/mrm.30631
BibTeX
@article{Kramer2025,
author = {Kramer, Mary K and Cerjanic, Alex M and Johnson, Curtis L},
title = {Fast, motion‐robust MR elastography with distributed, generalized encoding},
journal = {Magnetic Resonance in Medicine},
year = {2025},
volume = {94},
number = {5},
pages = {2113--2128},
doi = {10.1002/mrm.30631}
}
EUVIMED