Three‐dimensional high‐resolution T 1 mapping and perfusion imaging in the normal and ischemic rat brain with hyperpolarized [2‐ 13 C ] tertiary‐ butyl alcohol
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30535 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Mauricio Contreras und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Brain, Brain Ischemia, Magnetic Resonance Imaging. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NIA NIH HHS, NIBIB NIH HHS.
Abstract (Originalsprache)
Purpose
To develop methods for three‐dimensional relaxometry and quantitative perfusion imaging using hyperpolarized [2‐ 13 C] tertiary ‐butyl alcohol (TBA) in the rat brain under normal and ischemic conditions at 9.4 T. TBA is a freely diffusible tracer that readily traverses the blood–brain barrier, resulting in high tissue signal and long residence times.
Methods
A hybrid method consisting of rapid two‐dimensional imaging of the arterial input followed by slower three‐dimensional variable tip‐angle balanced steady state free‐precession imaging of the brain is implemented. Image data are analyzed to extract the signal amplitude and T 1,2 decay rates. Knowledge of the tracer's kinetics in tissue is used to determine blood flow.
Results
Effective T 1 relaxation rates in the rat brain range from about 15 to 20s. T 2 ranges from about 60 to 250 ms, with the shortest relaxation times found in the brainstem. In ischemic regions, the effective T 1 relaxation time is prolonged due to slower washout, whereas T 2 is largely unchanged. The technique yields flow rates in cortical gray matter ranging from 140 mL/100 g/min in normal brains to less than 30 mL/100 g/min in ischemic cases.
Conclusion
Hyperpolarized TBA provides sufficient sensitivity and tissue residence time to enable three‐dimensional mapping of relaxation and blood flow at 1.2–1.5‐mm 3 isotropic resolution in the rat brain. The technique has adequate signal‐to‐noise ratio in tissue with restricted flow. Raw images of the tracer can be acquired at 0.48 mm 3 isotropic resolution and signal‐to‐noise ratio of about 13 in cortical gray matter.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Surgery, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA.
- Department of Biomedical Engineering, University of Texas at Austin, Austin, Texas, USA.
- Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA.
ORCID-Profile: Gopal Varma, Aaron K Grant
Förderung
- NIH HHS
- NIA NIH HHS
- NIBIB NIH HHS
- National Institutes of Health
Zitieren
APA
Contreras, M., Callahan, C., Varma, G., & Grant, A. K. (2025). Three‐dimensional high‐resolution T 1 mapping and perfusion imaging in the normal and ischemic rat brain with hyperpolarized [2‐ 13 C ] tertiary‐ butyl alcohol. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30535
Vancouver
Contreras M, Callahan C, Varma G, Grant AK. Three‐dimensional high‐resolution T 1 mapping and perfusion imaging in the normal and ischemic rat brain with hyperpolarized [2‐ 13 C ] tertiary‐ butyl alcohol. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30535
BibTeX
@article{Contreras2025,
author = {Contreras, Mauricio and Callahan, Cody and Varma, Gopal and Grant, Aaron K},
title = {Three‐dimensional high‐resolution T 1 mapping and perfusion imaging in the normal and ischemic rat brain with hyperpolarized [2‐ 13 C ] tertiary‐ butyl alcohol},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30535}
}
EUVIMED