SNR ‐efficient whole‐brain pseudo‐continuous arterial spin labeling perfusion imaging at 7 T
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30527 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Joseph G Woods und 4 weiteren Autor:innen. Beteiligte Einrichtung: Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK. Hauptthemen laut MEDLINE: Brain, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Perfusion Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIHR Oxford Health Biomedical Research Centre, Wellcome Trust, UK BBSRC.
Abstract (Originalsprache)
Purpose
To optimize pseudo‐continuous arterial spin labeling (PCASL) parameters to maximize SNR efficiency for RF power constrained whole brain perfusion imaging at 7 T.
Methods
We used Bloch simulations of pulsatile laminar flow to optimize the PCASL parameters for maximum SNR efficiency, balancing labeling efficiency and total RF power. The optimization included adjusting the inter‐RF pulse spacing (TR PCASL ), mean B 1 + (B 1 + ave ), slice‐selective gradient amplitude (G max ), and mean gradient amplitude (G ave ). In vivo data were acquired from six volunteers at 7 T to validate the optimized parameters. Dynamic B 0 ‐shimming and flip angle adjustments were used to avoid needing to make the PCASL parameters robust to B 0 /B 1 + variations.
Results
The optimized PCASL parameters achieved a significant (3.3×) reduction in RF power while maintaining high labeling efficiency. This allowed for longer label durations and minimized deadtime, resulting in a 118% improvement in SNR efficiency in vivo compared to a previously proposed protocol. Additionally, the static tissue response was improved, reducing the required distance between labeling plane and imaging volume.
Conclusion
These optimized PCASL parameters provide a robust and efficient approach for whole brain perfusion imaging at 7 T, with significant improvements in SNR efficiency and reduced specific absorption rate burden.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.
- Department of Electronic Engineering and Information Science, School of Information Science and Technology, University of Science and Technology of China, Hefei, China.
- Institute of Science and Technology for Brain-inspired Intelligence, Fudan University, Shanghai, China.
ORCID-Profile: Joseph G Woods, Yang Ji, Hongwei Li, Aaron T Hess, Thomas W Okell
Förderung
- NIHR Oxford Health Biomedical Research Centre
- Wellcome Trust
- UK BBSRC
- National Natural Science Foundation of China
- Wellcome Trust and Royal Society
- Biotechnology and Biological Sciences Research Council
Zitieren
APA
Woods, J. G., Ji, Y., Li, H., Hess, A. T., & Okell, T. W. (2025). SNR ‐efficient whole‐brain pseudo‐continuous arterial spin labeling perfusion imaging at 7 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30527
Vancouver
Woods JG, Ji Y, Li H, Hess AT, Okell TW. SNR ‐efficient whole‐brain pseudo‐continuous arterial spin labeling perfusion imaging at 7 T. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30527
BibTeX
@article{Woods2025,
author = {Woods, Joseph G and Ji, Yang and Li, Hongwei and Hess, Aaron T and Okell, Thomas W},
title = {SNR ‐efficient whole‐brain pseudo‐continuous arterial spin labeling perfusion imaging at 7 T},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30527}
}
EUVIMED