EUVIMEDEUVIMED entdecken
Open Access

Ultrafast and robust T2 mapping using optimized single‐shot multi‐echo planar imaging with alternating blips

Mustafa Utkur iD, Liam Timms iD, Sila Kurugol iD, Onur Afacan iD

Magnetic Resonance in Medicine · 2025-08 · 94 (2) · 530-540

DOI: 10.1002/mrm.30516 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 28.04.2025. Verfasst von Mustafa Utkur und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Boston Children's Hospital and Harvard Medical School, Boston, Massachusetts. Hauptthemen laut MEDLINE: Echo-Planar Imaging, Brain, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS, NIDDK NIH HHS, National Institute of Diabetes and Digestive and Kidney Diseases.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop a rapid, motion‐robust mapping technique suitable for clinical use across the body, including traditionally challenging, motion‐prone patient populations or body parts.

Methods

A novel single‐shot multi‐echo spin‐echo EPI sequence with alternating phase encoding direction on each echo was implemented. This sequence acquires multiple echoes to measure from a single RF excitation. The alternating phase encoding gradient polarity enables the correction of geometric distortions in EPI using post‐processing software. Stimulated echoes were removed by optimizing spoiler gradients. Diffusion MRI can also be achieved by incorporating diffusion‐encoding gradients.

Results

Phantom experiments showed no significant difference between measured and reference values, indicating high precision and repeatability. In vivo, brain maps exhibited similar anatomical detail and tissue contrast as a reference sequence, with values of 70.0 4.0 ms for gray matter, 56.8 3.4 ms for the white matter at a magnetic field strength of 3 Tesla. High‐quality diffusion‐weighted images with minimal distortion were generated, even at high b‐values. mapping results from the kidney and fetal brain showcased the method's applicability across different anatomical regions and patient populations.

Conclusion

The single‐shot multi‐echo EPI sequence provided a basis for rapid, accurate relaxation mapping by correcting distortion and mitigating motion artifacts. This sequence enhances the clinical feasibility of quantitative mapping across diverse patient populations and body areas.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echo-Planar ImagingBrainImage Processing, Computer-AssistedHumansPhantoms, ImagingAlgorithmsReproducibility of ResultsDiffusion Magnetic Resonance ImagingMotionFemale

Stichwörter der Autor:innen

T2 mappingblip‐reversed encodinggradient spoilingmotion robustnesssingle‐shot EPI

Autor:innen und Institutionen

  • Department of Radiology, Boston Children's Hospital and Harvard Medical School, Boston, Massachusetts.

ORCID-Profile: Mustafa Utkur, Liam Timms, Sila Kurugol, Onur Afacan

Förderung

  • NINDS NIH HHS
  • NIDDK NIH HHS
  • National Institute of Diabetes and Digestive and Kidney Diseases
  • National Institute of Neurological Disorders and Stroke

Zitieren

APA

Utkur, M., Timms, L., Kurugol, S., & Afacan, O. (2025). Ultrafast and robust T2 mapping using optimized single‐shot multi‐echo planar imaging with alternating blips. Magnetic Resonance in Medicine, 94(2), 530-540. https://doi.org/10.1002/mrm.30516

Vancouver

Utkur M, Timms L, Kurugol S, Afacan O. Ultrafast and robust T2 mapping using optimized single‐shot multi‐echo planar imaging with alternating blips. Magnetic Resonance in Medicine. 2025;94(2):530-540. doi:10.1002/mrm.30516

BibTeX
@article{Utkur2025,
  author = {Utkur, Mustafa and Timms, Liam and Kurugol, Sila and Afacan, Onur},
  title = {Ultrafast and robust T2 mapping using optimized single‐shot multi‐echo planar imaging with alternating blips},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  volume = {94},
  number = {2},
  pages = {530--540},
  doi = {10.1002/mrm.30516}
}