Isotropic sampling of tensor‐encoded diffusion MRI
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30404 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Sune Nørhøj Jespersen. Beteiligte Einrichtung: Department of Clinical Medicine, Aarhus University, Aarhus, Denmark. Hauptthemen laut MEDLINE: Algorithms, Image Enhancement, Diffusion Magnetic Resonance Imaging, Diffusion Tensor Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: Lundbeck Foundation.
Abstract (Originalsprache)
Purpose
The purpose of this study is to develop a method for selecting uniform wave vectors for double diffusion encoding (DDE) to improve the accuracy and reliability of diffusion measurements.
Methods
The method relies on identifying orthogonal wave vectors with rotations, and representing these rotations as points on a three‐dimensional sphere in four dimensions using quaternions. This enables an electrostatic repulsion algorithm to achieve a uniform distribution of these points. The optimal points are then converted back into orthogonal wave vectors (or rotations).
Results
The method was validated by comparing the distribution of directions to those generated by uniform sampling and by evaluating the error in the powder‐averaged signal for various models. Our results demonstrate that the electrostatic repulsion approach effectively achieves a uniform distribution of wave vectors.
Conclusion
The proposed method provides a systematic way to generate uniform diffusion directions suitable, for example, for DDE, enhancing the precision of diffusion measurements and reducing potential bias in experimental results. The method is also capable of generating uniform sets of B‐tensors, and is thus applicable for general free waveform encoding.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
- Department of Physics and Astronomy, Aarhus University, Aarhus, Denmark.
ORCID-Profile: Sune Nørhøj Jespersen
Förderung
- Lundbeck Foundation
Zitieren
APA
Jespersen, S. N. (2025). Isotropic sampling of tensor‐encoded diffusion MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30404
Vancouver
Jespersen SN. Isotropic sampling of tensor‐encoded diffusion MRI. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30404
BibTeX
@article{Jespersen2025,
author = {Jespersen, Sune Nørhøj},
title = {Isotropic sampling of tensor‐encoded diffusion MRI},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30404}
}