Self‐gated free‐running 5D whole‐heart MRI using blind source separation for automated cardiac motion extraction
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30322 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Isabel Montón Quesada und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland. Hauptthemen laut MEDLINE: Algorithms, Heart, Principal Component Analysis. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Schweizerische Herzstiftung, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung.
Abstract (Originalsprache)
Purpose
To compare two blind source separation (BSS) techniques to principal component analysis and the electrocardiogram for the identification of cardiac triggers in self‐gated free‐running 5D whole‐heart MRI. To ascertain the precision and robustness of the techniques, they were compared in three different noise and contrast regimes.
Methods
The repeated superior–inferior (SI) projections of a 3D radial trajectory were used to extract the physiological signals in three cardiac MRI cohorts: (1) 9 healthy volunteers without contrast agent injection at 1.5T, (2) 30 ferumoxytol‐injected congenital heart disease patients at 1.5T, and (3) 12 gadobutrol‐injected patients with suspected coronary artery disease at 3T. Self‐gated cardiac triggers were extracted with the three algorithms (principal component analysis [PCA], second‐order blind identification [SOBI], and independent component analysis [ICA]) and the difference with the electrocardiogram triggers was calculated. PCA and SOBI triggers were retained for image reconstruction. The image sharpness was ascertained on whole‐heart 5D images obtained with PCA and SOBI and compared among the three cohorts.
Results
SOBI resulted in smaller trigger differences in Cohorts 1 and 3 compared to PCA ( p < 0.01) and in all cohorts compared to ICA ( p < 0.04). In Cohorts 1 and 3, the sharpness increased significantly in the reconstructed images when using SOBI instead of PCA ( p < 0.03), but not in Cohort 2 ( p = 0.4).
Conclusion
We have shown that SOBI results in more precisely extracted self‐gated triggers than PCA and ICA. The validation across three diverse cohorts demonstrates the robustness of the method against acquisition variability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.
- Department of Radiology, Mie University Hospital, Tsu, Japan.
- Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland.
- Woman-Mother-Child Department, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.
- CIBM Center for BioMedical Imaging, Lausanne, Switzerland.
ORCID-Profile: Isabel Montón Quesada, Augustin C Ogier, Ludovica Romanin, Christopher W Roy, Milan Prša, Jérôme Yerly, Ruud B van Heeswijk
Förderung
- Schweizerische Herzstiftung
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Zitieren
APA
Montón Quesada, I., Ogier, A. C., Ishida, M., Takafuji, M., Ito, H., Sakuma, H., Romanin, L., Roy, C. W., Prša, M., Richiardi, J., Yerly, J., Stuber, M., & van Heeswijk, R. B. (2025). Self‐gated free‐running 5D whole‐heart MRI using blind source separation for automated cardiac motion extraction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30322
Vancouver
Montón Quesada I, Ogier AC, Ishida M, Takafuji M, Ito H, Sakuma H, et al. Self‐gated free‐running 5D whole‐heart MRI using blind source separation for automated cardiac motion extraction. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30322
BibTeX
@article{MontnQuesada2025,
author = {Montón Quesada, Isabel and Ogier, Augustin C and Ishida, Masaki and Takafuji, Masafumi and Ito, Haruno and Sakuma, Hajime and Romanin, Ludovica and Roy, Christopher W and Prša, Milan and Richiardi, Jonas and Yerly, Jérôme and Stuber, Matthias and van Heeswijk, Ruud B},
title = {Self‐gated free‐running 5D whole‐heart MRI using blind source separation for automated cardiac motion extraction},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30322}
}
EUVIMED